Laserfiche WebLink
. <br /> � . <br /> New Construction Energy Code Compliance Certificate ����� ��� <br /> Per N 1101.8 Building Certihcate.A building certificate shall be posted in a pennanently visible location inside the uate Certificate Posted <br /> • building. i he certificate shall be complered by the builder a�id shall list infonnation and values of components <br /> IistedinTab1eN1101.8. ����• ��• <br /> Mailing Address o(the Dwelling or Dwelling L'nit Cih� <br /> 1860 Fox Street Orono 212320 <br /> Name of Hesidential Contracror MN I.icense Number <br /> SWANSON HOMES, LLC <br /> THERMAL ENVELOPE RADON SYSTEM <br /> Type: Check All That Apply X Passivc(No Fan) <br /> w <br /> o :� <br /> � � <br /> n, T Active(With fan and monometer or <br /> H p � other system monitoring device) <br /> � � � <br /> �a � a — � a � <br /> =� _ b ;a <br /> � a o � -o U � � � <br /> � ¢ m m s � � z � <br /> , � o �: N o a s, x o <br /> Insulntion Location � '� � � � V � � � r <br /> � � �° °.o � � � -o �ti <br /> � 7 � ^J rJ b � C ?D CO <br /> �° ,= z° 'r.�,'_, � � �.°, � z �, Other Please Describe Here <br /> Below Entire Slab �0 X <br /> Fbundatlon N��all �J X Type in location:interior eMerior or integral <br /> Perimeter of Slab on Grade 5 X <br /> Rim Joist(Foundation) 2 1/4�� X Type in location:interior ez�erior or integral <br /> n <br /> Rim Joist(1s'Floor+) 2 1/4 7ype in�ocation:intenor extenor or integra� <br /> H'ap 19 X <br /> ceiling,flat 44 X <br /> Ceiling,vaulted 35 X <br /> Bay Windows or cantilevered areas 35 X <br /> Bonus room over garagc 3$ X <br /> Describe other insulated areas <br /> Windows 8 Doors Heating or Cooling Duds Outside Conditioned Spaces <br /> Average U-Factor(exc/udes skvlights and one door)U: 0.31 Not applicable,all ducts located in conditioned spacc <br /> Solar Heat Gain Coeflicient(SHGC): 0.31 R-value <br /> MECHANICAL SYSTEMS Make-up Air Seleeta Type <br /> Applianeas Heating System Domestic Water Heater Cooling Systein X Not required per mech.code <br /> Fuel Type Nat Gas Nat Gas Elect Passive <br /> Manufacturer Br ant Rheem B ant Powe�'ed <br /> [nterlocked with e�aust device. <br /> Model AAV042100 Power Vent ANA13048 ���r�be: <br /> [nput in 100,000 Capaciry in 75 (hitput in 4 Othec,describe: <br /> Rating or Size BTUS: Galbns: I ons: <br /> Heat Loss: 80,1 16 Heat Gain: 40,841 Location of duct or system: <br /> Structure's Calculated <br /> AFUF'or y2 SFER: 13 <br /> HSPF°6 <br /> 48.000 <br /> Efficiencv Cfm's <br /> "round duct OR <br /> Meehanieal Ventilation Sysfem "metal duct <br /> Describe any additional or combined heating or cooling systems if installed:(c.g.two furnaces or air Combustion Air Select a Type <br /> source heat pump with gas back-up furnace): Not required per mech.code <br /> Select Type X Passive <br /> X Heat Recover Venrilator(HRV) Capacity in cfins: L,ow: I 10 High: 150 Other,describe: <br /> Energy Recover Ventilator(ER�Capacity in cfins: Low: High: L-ocation of duct or system: <br /> Continuous e�austing fan(s)rated capaciry in cfins: 100 Furnaee room <br /> Location of fan(s),describe: Main/Master/Panasonic Whisper Cfm's <br /> Capaciry continuous ventilation rate in cfins: ��Q 6" FLEX 4.2 <br /> Total ventilation(intermittent+continuous)rate in cfins: 330 "metal duct <br />