My WebLink
|
Help
|
About
|
Sign Out
Home
Browse
Search
1999-011708 - addition/remodel
Orono
>
Property Files
>
Street Address
>
F
>
Fox Street
>
1820 Fox Street - 03-117-23-42-0009
>
Permits/Inspections
>
1999-011708 - addition/remodel
Metadata
Thumbnails
Annotations
Entry Properties
Last modified
8/22/2023 4:38:09 PM
Creation date
10/13/2016 2:02:54 PM
Metadata
Fields
Template:
x Address Old
House Number
1820
Street Name
Fox
Street Type
Street
Address
1820 Fox St
Document Type
Permits/Inspections
PIN
0311723420009
Supplemental fields
ProcessedPID
Updated
There are no annotations on this page.
Document management portal powered by Laserfiche WebLink 9 © 1998-2015
Laserfiche.
All rights reserved.
/
41
PDF
Print
Pages to print
Enter page numbers and/or page ranges separated by commas. For example, 1,3,5-12.
After downloading, print the document using a PDF reader (e.g. Adobe Reader).
View images
View plain text
- - - - - _ _ _ _ _ _ - <br /> ' RHVAC-Residential 8 Light Commercial HVAC Loads Program � Elite Software Development,Inc. <br /> Ditter,Inc. Q Duncan MacMilliam <br /> ' Hamel,MN 55340-9691 Pa9e� ; <br /> - - - -- <br /> System #1 Zone#2 Summary Loads � <br /> _ _ _ _ _ _ _ -_ ____ - _._ -__ -- � <br /> - - - _ _ _ _ _ _ _ _ _ _ - - - - _ <br /> _ _ _ _ _ - - - - - <br /> Component Area Sen. Lat. Sen. Total <br /> ; Description _ _ Quan Loss Gain Gain Gain ' <br /> _ _ - - - - - - _ ._ _ _ - <br /> , 3E Window Double Pane Low Emit TIM Frame 332 12,187 0 13,138 13,138 ' <br /> 8M Glass Door pouble Clear Glass Wood Frame 126 6,388 0 5,187 5,187 <br /> 12G Wall R-13 + 3/4" ExtPoly Board(R-3.8) _ 1,382 8,264 0 2,119 2,119 i <br /> _ _ - - ___ - - - - - - _ _ <br /> Subtotals for structure: 1,840 26,839 0 20,444 20,444 � <br /> Active People: 10 0 2,300 3,000 5,300 <br /> Inactive People: 0 0 0 0 0 <br /> Appliances: 0 0 0 1,200 1,200 <br /> Lighting: p � p <br /> Ductwork: 0 0 0 0 0 ' <br /> Infiltration: Winter CFM: 168.4, Summer CFM: 112.3 458 17,041 2,747 2,470 5,217 ' <br /> Ventilation: Winter CFM: 91.1, Summer CFM: 110.0 0 n/a n/a n/a n/a <br /> - - - _ - - - __ - -- _ _ __ _ ____ - <br /> - - -- - - -- _ -_ _ <br /> Sensible Gain TotaL 27,114 ' <br /> Temperature Swing Multiplier: X1.00 <br /> --- - ---- -- - - ----- - <br /> - --- _ _ __ <br /> _Zone Load Totals:_ _ _ 43,880 _ 5,047 27,114 32,161 , <br /> _ _ - - - - _ __--- <br /> Check Figures 1 <br /> Supply CFM: 880 CFM per square foot: 0.394 <br /> Square feet of room area: 2,232 Square feet per ton: 811.709 <br /> - - - -- -- -_---- -------- <br /> Zone Loads - - <br /> ___ __ _ _ _ _ _ _ - - <br /> Total heating required with outside air: 43,880 Btuh 43.880 MBH <br /> Total sensible gain: 27,114 Btuh 84 % <br /> Total latent gain: 5,047 Btuh 16 % ' <br /> Total cooling required with outside air: 32,161 Btuh 2.68 Tons (based on sensible + latent) ' <br /> 2.750 Tons (based on 77% sensible capacity) � <br /> Saturday,July 10, 1999 <br />
The URL can be used to link to this page
Your browser does not support the video tag.