Laserfiche WebLink
INSPECTOR CHECKLIST - mound <br /> .iy6U tsaysitle Ktl.,Urono <br /> � WELL setbecks: 20'to pressure tested sewer line (5 psi for 15 min} <br /> 50'to everything t00'to dispersal area with shatlow weil <br /> PROPERTY LiNES se[back: 10'to everytMng <br /> Road setback: platted: 10'prop line. Metes&bounds:out of road easement,or outer ditch. <br /> LAKE/AI.UFF setbeck: 20'for bluff. Lakes:GD_,RD_,NE�. Protected wetland_. <br /> Buiiding setbacks: 10'for everything, 20'for dispersal area. <br /> WATER LINE under pressure se 10'to bed,tank 8 sewer line.{etse sewer line>12"below) <br /> � Sewer line&baffle connection (no 90's, 3'between 45's, slope min 1"in 8',max 2"in 8') <br /> (no depth req's, clean out every 900', Sch 40 pipe) <br /> � Septic tank and risers {water tight,insulated,proper depth,existing verified 6y pumping) <br /> mfq 1500 gallons none <br /> Riser over outlet, riser over inlet or center,and 6"+inspection pipe over any remaining baffles. <br /> No effluent filter 8 alarm <br /> Dose tank risers and plping (water tight,insulated,proper depth,drainback) <br /> mfq 1000 gallons <br /> � dose pump 47 gpm 14 head VERIFY Pt1MP CURVE 4.1 min ON 9 hr OFF <br /> � ftoat set[ing drop 8.8 inches at 22.0 gpi "DESIGNED" 5.4 inches approx float tether length <br /> 194.0 gat dose dfvided by gpi "INSTALLED'= lnches float drop(field corrected <br /> 11iBEL pump requirements and drawdown on riser or panet <br /> Cam lock reachable from grade-30"max. J-hook weep hole. Supply line access (no hard 90's) <br /> 2.0 inch suppty p1pe:Sch40, sloped 1/8"+, supported by 4"sch40 sleeve or compacted, and buried 6"+. <br /> splice box/control panet/electrical co�nections <br /> flow measurement:GT,ETM,time dosed,home water meter <br /> mound absorption area rough up <br /> mound rock dimensions 10.0 X 62.5 <br /> Sand lift depth 22 inches. (Jar test:2"sand leaves<1/8"silt after 30 min) <br /> � AbsorpYion Sand beyond rock 0.0 upslope 17.0 downslope <br /> � Bermed topsoil beyond rockbed 11 upslope 15 sidestope 21 downstope <br /> cover depth of 12-18"+ VERIFY <br /> 3 laterals (1-2'from edge of rock) <br /> 2.00 inch pipe size (Sch40 pipe&fittings) <br /> 3.0 ft lateral spacing <br /> e 1/4" inch perforations <br /> 3.0 ft perforation spacinq <br /> Air inlet at end of laterals, and at top feed manifold if necessary. VERIFY <br /> clean outs (no hard 90's) <br /> 4"inspection pipe to bottom of rock,anchored VERIFY <br /> Abandon exisiing system-if necessary �Re-use existing tank certification <br /> monitoring plan and type <br /> well abandonment form -if necessary <br /> � <br /> I <br /> � <br /> I <br /> � <br /> �� <br /> I <br /> I <br />