My WebLink
|
Help
|
About
|
Sign Out
Home
Browse
Search
2016-01287 - mechanical
Orono
>
Property Files
>
Street Address
>
B
>
Bridgewater Drive
>
758 Bridgewater Drive - PID: 33-118-23-11-0133 - New Address, New PID
>
Permits/Inspections
>
2016-01287 - mechanical
Metadata
Thumbnails
Annotations
Entry Properties
Last modified
8/22/2023 4:45:08 PM
Creation date
10/13/2016 8:51:25 AM
Metadata
Fields
Template:
x Address Old
House Number
758
Street Name
Bridgewater
Street Type
Drive
Address
758 Bridgewater Drive
Document Type
Permits/Inspections
PIN
3311823110133
Supplemental fields
ProcessedPID
Updated
There are no annotations on this page.
Document management portal powered by Laserfiche WebLink 9 © 1998-2015
Laserfiche.
All rights reserved.
/
9
PDF
Print
Pages to print
Enter page numbers and/or page ranges separated by commas. For example, 1,3,5-12.
After downloading, print the document using a PDF reader (e.g. Adobe Reader).
View images
View plain text
� �'� `-�' Z <br /> BUILDING LEAKAGE TEST <br /> Date of Test: 1/31/17 Technician: Jeff, Riccar Heating and Air Conditioning <br /> Test File: Wooddale 758 Bridgewater <br /> Customer: Wooddale Builders Buiiding Address: 758 Bridgewater <br /> Long Lake, MN <br /> Minnetonka, <br /> Phone <br /> Test Results <br /> 1. Airflow at 50 Pascals: 849 CFM ( +/-3.3%) <br /> (50 Pa= 0.2 w.c.) 1.44 ACH <br /> 0.23 CFM per ft2 floor area <br /> 2. Leakage Areas: 91.6 in2 ( +/-g.5 %)Canadian EqLA @ 10 Pa <br /> 50.0 in2 ( +/- 14.4%) LBL ELA @ 4 Pa <br /> 3. Minneapolis Leakage Ratio: 0.19 CFM50 per ft2 surface area <br /> 4. Building Leakage Curve: Flow Coefficient(C)= 74.4 ( +/-23.4%) <br /> Exponent(n) = 0.622 (+/-0.066) <br /> Correlation Coefficient= 0.96807 <br /> 5. Test Settings: Test Standard: = CGSB <br /> Test Mode: = Depressurization <br /> Equipment= Model 3 Minneapolis Blower poor, S/N 1 <br /> Infiltration Estimates <br /> 1. Estimated Average Annual Infiltration Rate: 67.3 CFM <br /> 0.11 ACH <br /> 22.4 CFM per person <br /> (using bedrooms+ 1) <br /> 2. Estimated Design Infiltration Rate: Winter: 90.3 CFM <br /> 0.15ACH <br /> Summer: 46.3 CFM <br /> 0.08 ACH <br /> 3. Recommended Whole Building Mechanical 58.7 CFM <br /> Ventilation Rate: (based on ASHRAE 62.2) <br /> Cost Estimates <br /> 1. Estimated Cost of Air Leakage for Heating: $ 57 per year heating <br /> 2. Estimated Cost of Air Leakage for Cooling: $ 5 per year cooling <br />
The URL can be used to link to this page
Your browser does not support the video tag.