Laserfiche WebLink
. Di�ision � - :�1�:T,1[,S <br /> � 05100 Stnictural Metal Franunk <br /> Steel brains shall be usecl if necessary and shall be sizecl according to <br /> ciurent engineering practice. ;�-�� �)�,�n� <br /> I�i��ision 6 - WOUD and PI ASTICS <br /> 06100 Rough Car�>entrX <br /> Floor joists shall be of 2 x 12 Hem/Fir material on 16" centers with <br /> 3/4" T&G plywood subfloor ghiecl and nailecl to joists. <br /> Exterior walls shall be of 2 x 6 SPF inaterial behind 1/2" OSB sheathing. <br /> Interior partitions shall be of 2 x 4 SPF inaterials. <br /> Roof sheathing shall be of 1/2"oriented strancl boazd. <br /> 06200 Finish CarpentrX <br /> Dcx�rs,windows,base and other areas as per plan shall be h-immecl <br /> oiit with two-piece Pine headlt>ed moulding on upper levels.Paneling <br /> ancl trim shall I�as noted on plan so that all trim is square and tnie. <br /> Di�•isiori 7_- THER1tAI. A1`'D MUISTURF PROTE TION <br /> 07100 Wat r�rootin� <br /> Exterior concrete masonry walls below gracle shall be coated with <br /> Owens-Cc,min�brand"Tuff-n-Dry"tnaterial and covececl with <br /> Owens-Corning brand "Warm-n-Dry rigid insulation board so as to <br /> Provide a system which carries a 10-year manufacturer's::mitecl <br /> warranty. Said system shall be used in conjunction with a clrain tile <br /> system capable of diverting any water away from the exterior walls. <br /> 07200 Insulation <br /> Perirneter below-�cie insulation shall be of eztruded polystyrene <br /> having an approximate R-value of 11. <br /> Finishecl basement walls shall be insulateci with R-11 fiberglass batts. <br /> Exterior 2 x 6 wood-frameci walls shail be insulatetl with R-19 <br /> fiberglass batts between studs. <br /> Roof insulation shall beblown fiberglass of an R=value of approximately <br /> 44 except in vaulted areas which will require hand-6atting with an <br /> achieved R-value of 24 to 38. <br /> 07300 Shingles - Roof " <br /> Roofing shall be of cnachine ctit ceclar shingles ap�lied over asphalt felts <br /> with a modifieci bitumen overlayment at eaves. <br /> 07461 Wocxl SidinQ <br /> Exterior walls shall be of machine cut cedar shingles applied over asphalt felts <br /> �vith a 6" ex���sure. <br /> 0763 l Gutters an�l Shert Metal <br /> Prefinishecl st�uldxrd "D" style�;utters shall be installeci along aPproPriate <br /> e<i��rs witl�d���vns�iouts provicle<I as necessary. <br /> I)i�•ision 8 - UOURti ;tnd ��'INDOW <br /> 08200 Wcxxl Doors <br /> Entry doi�r system shall be of Client's choice and is allowetl for. <br /> Interior doors shall be of 6-panel hemlock material with pine jambs <br /> or"French" tyPe doors as per plan. Sre O6�OZ <br /> 08361 Garage Overhead Doors <br /> Garage docns shall be of paintecl,woocl-panel docxs with individual openers. <br /> 08b00 Wooci Winclows <br /> Windows sha!?be of Vetter brand ponderosa pine sash and frame, <br /> casement type clacl in painteci aluminum.Glass shall be insulating type <br /> with low emissivity coating. ` <br /> 08700 Hardware <br /> All interior do<�r hardware shall be of polisheci brass lever type by <br /> Schlage. Entry hardware shall be of polished brass"Plymouth" type <br /> !�y S�h1aEe. <br /> 2 <br />