Laserfiche WebLink
� o� <br /> o :,, o , <br /> �� ��� '�'� CITY of ORONO <br /> � '���r���� � <br /> ?��a r�. .><� <br /> ��,, ��, ��,'�����,'��� �Fti Municipal Offices <br /> �� �'� ,,��-1���`�'.�G Street Address: Mailing Address: <br /> 9Ji'EgHOg' 2750 Keliey Parkway P.O. Box 66 <br /> Orono, MN 55356 Crystal Bay, MN 55323-0066 <br /> Owner: �,�n ���� Address: 1640 Fox St. <br /> Permit #'s: 2832, 1105 Dates: 8/23/71, 6/29/61 Contractors: Rotorooter, F & L <br /> (This is [� an existing system [ ] new construction) . <br /> SYSTEM COMPLIANCE (1-3) : 3 <br /> 1 Code System: Meets or exceeds current City standards in all respects relating to design, <br /> construction, and location. Appears to be operating properly. <br /> 2 Compliant System: Does not meet all current City standards for new construction, but in <br /> most respects appears to be designed, located, and constructed in accordance with previous <br /> � codes and is functioning properly. <br /> ' Non-Compliant System: System may or may not meet current City standards for design, <br /> construction, or location, but is failing to properly treat and dispose of the current <br /> input; and any system with less than three feet of vertical separation between the bottom <br /> of the drainfield and the saturated soil level. <br /> (The saturated soil lavel [�] has or [ ] has not been identifiad at this time. If the <br /> saturatad soil lavel has not been identified, this classification is subject to revision.) <br /> TANK CONDITION (5-9) : 6 <br /> S Pumpout not needed at this time. <br /> C'o� Solids accumulation in tanks indicates they should be pumped out this year. <br /> 7 System is discharging to the surface. Tanks must be pumped out within 48 hours. <br /> 8 Inspection risers missing-tanks could not be inspected. If tanks have not been pumped out <br /> within three years, they should be pumped out and risers installed now. <br /> 9 Inspection pipe is located over tank baffle-can not measure solids accumulation. If tanks <br /> have not been pumped out within three years, they should be pumped out now. <br /> (During the last septic tank Maintenance Pumpout tha tanks [ ] ware or [x] were not confirmed <br /> to be watertight by the licensad pumping contractor. If the tanks wera not confirmed to be <br /> watartight, this classification is subject to revision.) <br /> D INFIELD CONDITION (11-14) : 11 <br /> Drainfield is dry, no surfacing evident. <br /> 12 Some evidence of surfacing, not critical yet. Repair is not required at this time. <br /> 13 Drainfield is saturated and visibly discharging untreated effluent to the surface. <br /> Contact the City Inspector immediately. Repair must be completed within 90 days. <br /> 14 Drainfield extent and condition unknown. <br /> POTENTIAL FOR SYSTEM FAILURE: (system age and condition, soils, etc. ) : medivm <br /> COMMENTS: In order to confirm that your septic system meets Minnesota standards, soil borings <br /> were performed to verify a 3 foot separation between the drainfield and the seasonal water <br /> table. The separation is 0 feet and the system is non-compliant. Repair or replacement of the <br /> septic system is required by 12/31/2007. <br /> ���=97 ,��--- <br /> Da e of Inspection Se ic System Inspector <br /> Note: In the event that this inspection report is used to satisfy the requirements for a <br /> transfer of property, this report does not guarantee that an existing system will continue to <br /> function properly, but indicates the operation of the system under current conditions. <br /> Telephone (612) 473-7357 • FAX 473-0510 <br />