Laserfiche WebLink
�-�,\ <br /> �� O� � <br /> ;� <br /> � � <br /> ;�;� � � '��, <br /> '� �� �� CITY of ORONO <br /> , � rY � � <br /> �`� '� +x '�?;; s ;. �, ; Municipal Offices <br /> '� '' � , ��=�, �j,�/� <br /> Street Address: qsa-a4q'y6o O Mailing Address: <br /> �`9$ESKpg'� 2750 Kelley Parkway P.O. Box 66 <br /> -- Orono, MN 55356 Crystal Bay, MN 55323-0066 <br /> To Current Owner: Address: �S�o �-ax S�,, <br /> City Ordinance 199 requires that each existing on-site sewage treatment system in Orono be inspected every two years. <br /> The on-site sewage treatment system at the above address has been inspected and appears to fall into the categories checked below. <br /> STEM CONFORMIT'Y 1-3 : � <br /> 1 "CODE SYSTEM" An LSTS which meets all the location,design and construction standards of the current Orono Municipal Code. <br /> 2 "COMPLIANT SYSTEM" An ISTS which does not meet all the location,design and construction standards of the current Orono <br /> Municipal Code but does meet the tluee foot separation requirement or two foot requirement for systems installed 1996 or earlier,and <br /> which is not failing or an imminent threat to public health or safety. <br /> 3 "NON-COMPLIANT SYSTEM" A prohibited ISTS;an ISTS located within a designated 100-year flood piain,any ISTS which may <br /> or may not meet all the location,design,or construction stan�rds of the current Orono Municipal Code and which is failing for any <br /> reason;and any ISTS with less than three feet of unsaturated soil or sand between the distribution device and the limiting soil characteristics. <br /> TANK CONDITION(5-7): �� <br /> Tank inspection indicates: <br /> �Pumpout not needed at this time. <br /> 6 Septic tanks must be pumped out this year (city code recommends tanks to be pumped out once every 3 years. <br /> Tank was last pumped �- �� -� �� ). <br /> Make sure septic tanks are pumped through manhole and not throu�h white inspection pipes. This allows for the proper <br /> cleaning. Keep water softner and iron filter discharge out of septic system to prolong life of drainfield. Ask pumper to test <br /> alarm float to verify alarm is still workin�in vour house. The alarm warns owner that septaQe is about to backup into basement. <br /> 7 Inspection risers missing-tanks could not be inspected. Inspection risers(4" dia.pipe)must be installed in each tank. If <br /> tanks have not been pumped out within the last three years,they should be pumped out now. <br /> D INFIELD CONDITION 8-10 : � <br /> 8 Drainfield is dry,no surfacing evident. <br /> Some evidence of surfacing,not critical yet. <br /> 10 Drainfield is saturated and visibly discharging untreated effluent to the surface. Contact the City Inspector <br /> immediately.Repairs must be completed within 90 days. <br /> COMMENTS: M� �—� � o�K-S � I�_ �"u�- Se f�� -�-��k.� >-� <br /> �'Lcy ��v� �b� �tr` ��`"�(�� ri-�•�-. ��,Sfi 3 �ve�,r1, <br /> �Zo—o'-� �� � '� <br /> Date of Inspection Matt Bolterman - Septic System Inspector <br /> Note: In the event that this inspection report is used to satisfy the requirements for a mortgage or other transfer of property, be advised that this report does <br /> not guarantee or certify that an existing system will continue to function properly, but is merely an opinion of the adequacy of the system under current <br /> conditions based on the available information. <br />