GENERALNOTES <br /> 1. DO NOT BACKFILL BASEMENT WALLS UNTIL THE CONCRETE HAS REACHED A MINIMUM COMPRESSIVE <br /> STRENGTH OF 2,250 PSI. IN ADDITION, DO NOT BACKFILL UNTIL THE BASEMENT WALLS ARE LATERALLY <br /> SUPPORTED BY THE FINAL INSTALLED FLOOR CONSTRUCTION AT THE TOP AND BOTTOM, UNLESS <br /> ADEQUATE SHORING IS INSTALLED AS REQUIRED. SHORING IS THE SOLE RESPONSIBILITY OF THE GENERAL <br /> CONTRACTOR. <br /> 2. STRIP FOOTING MAY BE PLACED AT ELEVATIONS LOWER THAN SHOWN IN THE DETAILS. <br /> 3. 1Y2" DEEP BY 3%"WIDE BY CONTINUOUS KEYWAYS MAY BE USED IN LIEU OF DOWELS FOR FULL HEIGHT AND <br /> FROST WALLS. <br /> 4. STRIP FOOTING TO WALL CENTERLINES MAY BE OFFSET UP TO 2", HOWEVER, A MINIMUM OF 2" OF STRIP <br /> FOOTING IS TO EXTEND BEYOND THE WALL FACE ON EACH SIDE. <br /> 5. PROVIDE CODE REQUIRED FROST PROTECTION TO THE BOTTOM OF ALL FOOTINGS. <br /> 6. SLOPE GRADE DOWN AND AWAY FROM THE STRUCTURE A MINIMUM OF 6"WITHIN THE FIRST TEN FEET <br /> UNLESS ADEQUATE DRAINAGE OR SWALES ARE PROVIDED, <br /> 7. BOTH MATERIALS AND INSTALLATION OF DRAIN TILE, WATER-PROOFING, CONTROL JOINTS, FLASHING, AND <br /> INSULATION ARE TO BE IN ACCORDANCE WITH THE CODE BY THE GENERAL CONTRACTOR, UNLESS NOTED <br /> OTHERWISE. <br /> 8. ALL WALL WIDTHS SHOWN ARE NOMINAL DIMENSIONS, UNLESS NOTED OTHERWISE. OVERALL WALL <br /> THICKNESS MAY VARY BY UP TO y" FROM THAT SHOWN ON THE DRAWINGS. <br /> 9. REINFORCING PLACEMENT TOLERANCE IS NOT TO EXCEED 2". BARS BEING SPLICED ARE TO BE WITHIN 2" <br /> OF CENTERLINE. MINIMUM SPLICE LENGTHS ARE 30 BAR DIAMETERS FOR GRADE 40 STEEL AND 48 BAR <br /> DIAMETERS FOR GRADE 60 STEEL. TYING IS NOT REQUIRED PROVIDED THESE TOLERANCES ARE MET. <br /> 10.PROVIDE MATCHING HOOK BARS FOR ALL HORIZONTAL BARS AT WALL CORNERS AND INTERSECTIONS. <br /> HORIZONTAL BARS MAY BE PLACED ANYWHERE WITHIN THE WALL AS LONG AS A 2" MINIMUM CLEAR COVER <br /> IS ACHIEVED ON ALL SIDES. <br /> 11.REINFORCING MAY BE BUNDLED UP TO A MAXIMUM OF THREE BARS. <br /> 12.DOWELS MAY BE DRILLED AND GROUTED IN PLACE. VERTICAL BARS AND DOWELS DO NOT NEED TO ALIGN. <br /> VERTICAL BARS MAY BE DRILLED AND EMBEDDED 5" INTO THE STRIP FOOTING IN LIEU OF DOWELS. <br /> 13.THE BOND BETWEEN CONCRETE AND REINFORCING WILL NOT BE APPRECIABLY REDUCED IF VERY MINOR <br /> FORM OIL IS PRESENT FOR THE CONDITIONS CONTAINED WITHIN THESE DRAWINGS. <br /> 14.SILL PLATES ARE TO BE ANCHOFiED WITH A MINIMUM OF TWO ANCHORS PER SILL SECTION. ALL SECTIONS <br /> ARE TO HAVE AN ANCHOR WITHIN 4"TO 12"OF EACH END. AN ANCHOR IS TO BE PLACED AT ALL WALL <br /> CORNERS AND INTERSECTIONS ON WALLS MORE THAN TWO FEET IN LENGTH. WALLS TWO FEET OR LESS IN <br /> LENGTH REQUIRE A MINIMUM OF ONE ANCHOR. REQUIREMENTS FOR SHEAR WALLS AND BRACED PANELS <br /> MAY BE IN EXCESS OF THESE FiEQUIREMENTS. TWO INCH WASHERS ARE ONLY REQUIRED AT FULL HEIGHT <br /> FOUNDATION WALLS. BUILDING DESIGNER IS TO ACCOMMODATE LOAD PATH FOR ANY VERTICAL LOAD <br /> TRANSFER OVER A SILL PLATE OVERHANG CONDITION. <br /> 15.ANCHOR BOLTS%2" DIAMETER OR LARGER ARE NOT REQUIRED TO BE CORROSION PROTECTED IN <br /> ACCORDANCE WITH CODE SECTION R317.3.1 EXCEPTION 1. <br /> 16.ALL PRE-MANUFACTURED FASTENERS AND CONNECTORS ARE TO BE INSTALLED IN ACCORDANCE WITH <br /> THE MANUFACTURER'S REQUIREMENTS. <br /> 17.FLOOR BLOCKING IS ONLY REQUIRED AT FULL HEIGHT FIRST FLOOR NON-BEARING FOUNDATION WALLS. <br /> 18.CARE IS TO BE TAKEN DURING CONCRETE PLACEMENT TO MINIMIZE INADEQUATE HORIZONTAL AND <br /> DIAGONAL COLD JOINTS, AND TO PREVENT THESE JOINTS ENTIRELY IN WALLS WITHOUT VERTICAL <br /> REINFORCEMENT. ADEQUATELY VIBRATE CONCRETE AT POTENTIAL JOINT LOCATIONS AS REQUIRED, <br /> BASED ON PLACEMENT CONDITIONS TO ELIMINATE HONEYCOMBING AND TO ENSURE SUFFICIENT BONDING <br /> IS ACHIEVED. <br /> 19.TOP AND BOTTOM OF FOUNDATION WALLS ARE TO BE LATERALLY SUPPORTED PRIOR TO BACKFILLING. <br /> MEANS AND METHODS OF LATERAL SUPPORT ARE BY OTHERS. <br /> 2016 C.I.P. CONCRETE FOUNDATION SITE ADDRESS: Date Rev <br /> -«� °��-r"-' GUIDELWE DRAWINGS <br /> --_ . _. <br /> c;�NERAL NOTES Praject: <br /> r <br /> 4'��� ��CI Concrete Inc. <br /> �9175 Isanti Street NE c�ty: sta�e: MN z�p: <br /> ''0"`''"'`'�`11e"°`''', glaine, MN 55449 1 <br /> su��e a Pro ect Number: 6.001 /� ^ <br /> Plymouth,MN55447 Drawing Date: January 1,2016 `� <br /> rei siz-7oa-35�2 Client: Sheet: 2 of 15 V L. <br /> ww�v.hanson rou mn.com <br /> � COPYRIGHT HANSON GROUP LLC 2016 <br />