Rhvac-Residentiai 8 Light Commercial HVAC Loads -� Elite Software Development,Inc. <br /> Riccar Heating and Cooling Wooddale Hausten/Lynch Res. <br /> Andover, MN 55304 <br /> -- Pa e 2 <br /> Total Building Summary Loads <br /> Component Area Sen Lat Sen Total <br /> Descri tion Quan Loss Gain Gain Gain <br /> 4A-6-d: Glazing-Double pane low-e (e=0.20 or less), 118.4 3,321 0 1,123 1,123 <br /> high performance, sliding glass door, e=0.05 on <br /> surface 2, any frame, outdoor insect screen with 50% <br /> coverage, u-value 0.33, SHGC 0.33 <br /> Andersen: Glazing-operable window, wood sash, u-value 368.4 9,082 0 7,916 7,916 <br /> 0.29, SHGC 0.32 <br /> Andersen: Glazing-operable window, wood sash, outdoor 7�.2 1,757 0 2,160 2,160 <br /> insect screen with 50°10 coverage, u-value 0.29, <br /> SHGC 0.32 <br /> 11 N: Door-Metal-Polystyrene Core 48 1,428 0 404 404 <br /> 12F-Osw: Wall-Frame, R-21 insulation in 2 x 6 stud 1975.5 10,915 0 1,707 1,707 <br /> cavity, no board insulation, siding finish, wood studs <br /> 1560-10sf-8: Wail-Basement, , R-10 board insulation to 955.5 4,704 0 17g 17g <br /> floor, no interior finish, 8'floor depth <br /> 166-50: Roof/Ceiling-UnderAtticwith Insulation on Attic 1818 3,091 0 1,745 1,745 <br /> Floor(also use for Knee Walls and Partition <br /> Ceilings), Vented Attic, No Radiant Barrier, Dark <br /> Asphalt Shingles or Dark Metal, Tar and Gravel or <br /> Membrane, R-50 insulation <br /> 21A-32: Floor-Basement, Concrete slab, any thickness, 2 1800 3,060 0 0 p <br /> or more feet beiow grade, no insulation below floor, <br /> any floor cover, shortest side of floor slab is 32'wide <br /> 20P-30: Floor-Over open crawl space or garage, Passive, 18 54 0 5 � <br /> R-30 blanket insulation, any cover_ <br /> --------__---- ---- --------------- <br /> Subtotals for structure: 37,4�2 0 15,239 15,239 <br /> People: 5 1,000 1,150 2,150 <br /> Equipment: 1,170 7,21g g,3gg <br /> Lighting: p � 0 <br /> Ductwork: 0 0 0 0 <br /> Infiltration: Winter CFM: 47, Summer CFM: 23 4,234 362 324 686 <br /> Ventilation: Winter CFM: 132, Summer CFM: 132 4,790 2,048 733 2,780 <br /> Exhaust: Winter CFM: 132, Summer CFM: 132 <br /> Humidification (Winter) 8.20 gal/day: 3,009 0 0 p <br /> AED Excursion: 0 0 2,99g 2,ggg <br /> ------ -------------- ----- ----------------------- <br /> Total Buiiding Load Totals: 49,444 4,580 27,664 32,243 <br /> Check Fi ures <br /> Total Building Supply CFM: 1,262 CFM Per Square ft.: 0.349 <br /> Square ft. of Room Area: 3,618 <br /> Volume (ft') of Cond. Space: 35,262 <br /> Buildin Loads <br /> Total Heating Required Including Ventilation Air: 49,444 Btuh 49.444 MBH <br /> Total Sensible Gain: 27,664 Btuh 86 % <br /> Total Latent Gain: 4,580 Btuh 14 % <br /> Total Cooling Required Including Ventilation Air: 32,243 Btuh <br /> Notes <br /> Rhvac is an ACCA approved Manual J and Manual D computer program. <br /> Calculations are performed per ACCA Manual J 8th Edition, Version 2, and ACCA Manual D. <br /> All computed results are estimates as building use and weather may vary. <br /> Be sure to select a unit that meets both sensible and latent loads according to the manufacturer's performance data at <br /> your design conditions. <br /> C:1UserslKurtlDocuments\Elite Software\Rhvac 9 Projects\Woodale Hausten res..rh9 Monday, August 22, 2016, 1:46 PM <br />