My WebLink
|
Help
|
About
|
Sign Out
Home
Browse
Search
1999-012089 - new septic system
Orono
>
Property Files
>
Street Address
>
F
>
Fox Street
>
1465 Fox Street - 02-117-23-33-0002
>
Septic
>
1999-012089 - new septic system
Metadata
Thumbnails
Annotations
Entry Properties
Last modified
8/22/2023 4:09:34 PM
Creation date
10/6/2016 1:58:56 PM
Metadata
Fields
Template:
x Address Old
House Number
1465
Street Name
Fox
Street Type
Street
Address
1465 Fox St
Document Type
Septic
PIN
0211723330002
Supplemental fields
ProcessedPID
Updated
There are no annotations on this page.
Document management portal powered by Laserfiche WebLink 9 © 1998-2015
Laserfiche.
All rights reserved.
/
19
PDF
Print
Pages to print
Enter page numbers and/or page ranges separated by commas. For example, 1,3,5-12.
After downloading, print the document using a PDF reader (e.g. Adobe Reader).
View images
View plain text
S,�P TESTING, INC. Steven B. Schirmers — MPCA Cert. No. 627 <br /> � 951 Katydid Lane NE • St. Michaei, MN 55376 • (612) 497-3566 <br /> . <br /> July 16 , 1995 <br /> Robert :-iare ---� <br /> 1465 Fox S�ree� � � � �k�f i y,/ ���„ <br /> Orono, �?enn. Co . , �iN <br /> This On-Site Sewage Treat,>:ent System is Designed for a Type l, five <br /> bedroom home Designed in accordance with the Minnesota Pollution <br /> Control Agency Cha�ter 70E0 and local ordinances . <br /> This siLe has an existing Non-Conforming system which is less than <br /> 3 ' from the highest known saturated layer of soil (mottled soil ) . <br /> Soil Borings in the area oi the existing system indicated mottled <br /> soil at 18" to 30" below the surface . The existing tanks & pumping <br /> chamber may be used upon a�proval by the local Inspector . The <br /> tanks must be water tight. The manhole on the pumping chamber is <br /> a block type and must be replaced & surface runoff diverted away <br /> from the tanks if used . <br /> The soils on this site are a clay loam. Mottled Soil was located <br /> at 24" & 26" . Due to the seasonally saturated soil a Pressurized <br /> Mound System must be installed to treat septic effluent. The rock <br /> bed must be located at least 3 ' above the seasonally high water table. <br /> The soils at a depth of 12" have a percolation rate averaging <br /> 6 . 1 min/inch. <br /> A pump�ng chamber will need to be installed to lift the effluent <br /> to the treatment area . <br /> The property lines are approximated and must be located prior to <br /> installing the system to the south & east. <br /> The manifold and supply line pipe must have back drainage to the <br /> pumping chamber . The distribution pipes shall have their ends <br /> capped . Be sure the rock and sand fill material-+are clean. The <br /> sod layer below the entire mounded area must be turned over, just <br /> break up the sod, be sure not to over work. <br /> The power supply and switches must be located outside the manhole <br /> and pumping chamber in a weather proof enclosure . A warning device <br /> must be installed with a light and sound device, this is in case of <br /> a pump failure . <br /> CONT' D <br />