TSX-8500
<br /> �YPICA'L PHYSICAL PROPERTIES Water-Resistive Barrier -When TSX-8500 is installed uver wood
<br /> Physical properties shown are based on data obtained under controlled or steel studs with the joints sealed, it serves as a Wat�r-Resistive
<br /> conditions and are subject to normal manufacturing tolerances. Barrier. TSX-8500 has been tested per the guidelines set forth in the
<br /> ICC-ES Acceptance Criteria for Foam Plastic Sheathing Panels Used
<br /> . .,. . „ as Water-Resistive Barriers (AC71). For use as a WRB, TSX-8500
<br /> Density,Overa�l,Nomina� ASTM D1622 2.o pcf shaii be instalied with board joints placed directiy over wopd or steel
<br /> framing spaced a maximum of 24 inches o.c.All insulation board joints
<br /> Compressive Strength' ASTM D1621 2o psi Standard shaii be covered by R-SEAL 3000 tape. All transitions and throughwall
<br /> Also Available in 25 psi penetrations must be flashed to comply with applicabie code.
<br /> Upon Request
<br /> Flame Spread, Facedz ASTM E84 25 or Less Exterior Walls - TSX-8500 can be specified in exterior walis of
<br /> buildings of any height utilizing brick veneer,stucco, limestone or natural
<br /> Smoke Developed, Faced2 ASTM E84 <450 stone veneer,cast artificial stone veneer,MCM,ACM,terracotta cladding,
<br /> Water Vapor Transmission ASTM E96 <0.03 Perm metal skin,cement board siding,stonelaluminum honeycomb composite
<br /> Water Absorption ASTM C209 <0.2%Vol. panels, AAC panels or thin brick. TSX-8500 has been tested per
<br /> Dimensional Stability ASTM D2126, <2%Linear Change NFPA 285 and successfully passes with the exposed side facing the
<br /> 7 days,158°F,se%RH exterior. The NFPA 285 listinglapproval is dependent on all components
<br /> Reflectance ASTM E408 0.96 of the assembly. For a full explanation of approved assemblies and
<br /> Emittance 0.04 acceptabie components,refer to Rmax Architectural Solutions:NFPA 285
<br /> and Exterior Walls with Rmax TSX-8500. Third party evaluations and
<br /> Air Permeance ASTM E2178 <0.02 u(s.mz) listings should also be consulted for specific instructions.
<br /> Service Temperatures -40°F to+250°F
<br /> � .�• .� ,�,..`..��=—�-'�___ p
<br /> �.
<br /> � •.� . � � �- � � , �. � , „ . , . --��".�-.�.. ' �
<br /> �, • ••� � '� ' ' �- � • � : (1 . � • •� � r• • �' �( � ---- -- STEELSTUDS
<br /> .� X.', I 3-� ,�
<br /> � � � g�� � � � - TSX-6500
<br /> 7 �" � /
<br /> � ' �'� %--� ACM/MCM PANEL
<br /> APPLlCATIf�N / INSTALLATION - �
<br /> General - TSX-8500 passes UL1715 (walls only or ceilings ��'
<br /> only) in single or multiple layers without joint treatment of any _ ` ,,�'"
<br /> kind. Therefore, the boards only need to be tight�y butted. ,�✓y ;
<br /> However, taping the seams is acceptable using R-SEAL 3000, ��
<br /> or equivalent. For a more professional, finished look, use Rmax's �
<br /> PVC insulation clip. Refer to Rmax publication, Joint Closure
<br /> Recommendations and Installation Instructions for Interior Exposed
<br /> Applications, for additional information and guidelines on installation,
<br /> joint treatment and sealing techniques. TSX-8500 may be covered with pre-Engineered Metal Build9ngs-TSX-8500 provides a layer of
<br /> an interior finish product provided it is compliant with the requirements of continuous insulation (ci) for walls or ceilings of pre-engineered metal
<br /> IBC Chapter 8, including interior paint.A quality grade acrylic latex paint buildings in one easy step. The TSX-8500 is simply fastenetl to the face
<br /> is recommended for coating the surface. While primer is not generally of the girts or between the girts and the metal exterior skin of the building.
<br /> required,consult the paint manufacturer andlor industrial paint supply for Use Rmax PVC clips for an easy yet clean, professional installation.
<br /> recommendations and best practice.
<br /> Securement — TSX-8500 may be fastened to wood framing using
<br /> roofing nails, bugle head screws or minimum 314 inch cap nails. The ,��
<br /> fasteners shall be long enough to penetrate wood framing a minimum ,�; ' `��
<br /> of 1 inch. TSX-8500 may be fastened to metal framing using self-taping ;�''�J,
<br /> screws and plastic washers. The fasteners shall be long enough to _ ,_� ' �",�--`� °
<br /> penetrate metal framing a minimum of four threads. Wherever possible,
<br /> the insulation boards shall be installed vertically with all edges tightly s�oEwa����Rr --- ,� . ,� `
<br /> butted and backing by framing. When the insulation boards are installed rsx-asoo -��'" ��
<br /> horizontaily, i.e., perpendicular to framing, the maximum span shall be �_ � — ' r:_
<br /> 5 feet. TSX-8500 ma be secured to concrete surfaces usin lastic R-sen�300o Tnae � _• ;,
<br /> y g p {OPTIONAL) � y
<br /> masonry fasteners with washer or a quality grade construction atlhesive, k �!
<br /> a � =_s �.�
<br /> ;
<br /> , _ �.
<br /> i , ', , �,
<br /> _ __-i_ _i�---;..: - - C �,
<br />
|