Laserfiche WebLink
r ' ' ' <br /> [ ] � Joints, penetrations, and all other such openings in the building envelope that are sources of air <br /> � leakage must be sealed. <br /> [ ] � Recessed lights must be 1)Type IC rated, or 2)installed inside an appropriate air-tight assembly <br /> � with a 0.5" clearance from combustible materials. If non-IC rated,the fixture must be installed with a <br /> � 3" clearance from insulation. <br /> � <br /> � Vapor Retarder: <br /> [ ] � Required on the warm-in-winter side of all non-vented framed ceilings,walls, and floors. <br /> � <br /> � Materials Identification: <br /> [ ] � Materials and equipment must be identified so that compliance can be determined. <br /> [ ] � Manufacturer manuals for all installed heating and cooling equipment and service water heating <br /> � equipment must be provided. <br /> [ ] � Insulation R-values,glazing U-factors, and heating equipment efficiency must be clearly marked on <br /> � the building plans or specifications. <br /> � <br /> � Duct Insulation: <br /> [ ] � Ducts in unconditioned spaces must be insulated to R-5. <br /> � Ducts outside the building must be insulated to R-8.0. <br /> � <br /> � Duct Construction: <br /> [ ] � All ducts must be sealed with mastic and fibrous backing tape. Pressure-sensitive tape may be used <br /> ( for fibrous ducts. Duct tape is not permitted. <br /> [ ] � The HVAC system must provide a means for balancing air and water systems. <br /> � <br /> � Temperature Controls: <br /> [ ] � Thermostats are required for each separate HVAC system. A manual or automatic means to <br /> � partially restrict or shut off the heating and/or cooling input to each zone or floor shall be provided. <br /> � <br /> � Circulating Hot Water Systems: <br /> [ ] � Insulate circulating hot water pipes to the levels in Table 1. <br /> � <br /> � Swimming Pools: <br /> [ ] � All heated swimming pools must have an on/off heater switch and require a cover unless over 20% <br /> � of the heating energy is from non-depletable sources. Pool pumps require a time clock. <br /> � <br /> � Heating and Cooling Piping Insulation: <br /> [ ] � HVAC piping conveying fluids above 120 �'or chilled fluids below 55 °F must be insulated to the <br /> � levels in Table 2. <br />