My WebLink
|
Help
|
About
|
Sign Out
Home
Browse
Search
2005-P08970 - new structure
Orono
>
Property Files
>
Street Address
>
F
>
Forest Lake Landing
>
4460 Forest Lake Landing - 07-117-23-24-0015
>
Permits/Inspections
>
2005-P08970 - new structure
Metadata
Thumbnails
Annotations
Entry Properties
Last modified
8/22/2023 5:32:53 PM
Creation date
9/28/2016 12:24:23 PM
Metadata
Fields
Template:
x Address Old
House Number
4460
Street Name
Forest Lake
Street Type
Landing
Address
4460 Forest Lake Landing
Document Type
Permits/Inspections
PIN
0711723240015
Supplemental fields
ProcessedPID
Updated
There are no annotations on this page.
Document management portal powered by Laserfiche WebLink 9 © 1998-2015
Laserfiche.
All rights reserved.
/
17
PDF
Print
Pages to print
Enter page numbers and/or page ranges separated by commas. For example, 1,3,5-12.
After downloading, print the document using a PDF reader (e.g. Adobe Reader).
View images
View plain text
� Site Address: Ciry of orono <br /> ' 'pg'��'p`� <br /> ,��;, <br /> "CATEGORY 1" ALTERNATE FOR ��� ���� F�' <br /> �x � ,r <br /> ��9���¢4�G... <br /> ONE & TWO FAMILY DWELLINGS 952-249-4600 <br /> I�vST[tuC7'�o1vs: This alternative may be used for one-and two-family dwellings built to meet the Category 1 requirements of Minnesota <br /> Rules,Chapter 7670. Complete Parts A,B,and C. Clearly mark plans with: insulation R-values; window and skylight U-values;size and type of <br /> equipment; equipment controls; and location of vapor retarder and windwash barriers. More detailed infonnation can be found in the A7i�7Jzesota <br /> E�zerw Coc�e summary sheets available fi-om the Minnesota Department of Commerce. <br /> Part A. BUILDING ENVELOPE <br /> Check proposed envelope joint sealing option � v[� Prescriptive(caulking,gaskets,etc.) ❑ perfornlance(test per 7670.0470 subp. 7.C.� <br /> Check thennal energy calculation option used� [�`Cookbook" (complete worksheet below) � MnCheck method(attach repert) <br /> � Perfonnance (attach U-value calculations) � Systems Analysis method(attach analysis) <br /> ��Cookbook�� Worksheet MINiMUM REQUIREMENTS <br /> for"Cookbook"o tion ont ) <br /> Ceiling Insulation: Minimmn R-38 with 7%s"energy heel; or <br /> INSrRUCT[ONS Minimum R-44 with low truss heel; or <br /> Step l. Check itein(s)that design ineets on Minrmum Requirenie�ats list Minimum R-38 with R-5 sheathin when no attic. <br /> to the right.Must meet all items to use"Cookbook"option. Entry Doors: Max. U-value of 0.30 or 1'/<"solid wood with stonn <br /> Step 2. Indicate proposed wall type on table below. L'� Rim Joist Insulation: Minimum R-l9 <br /> Step 3. Indicate Window U-value and source. Floors over unconditioned s aces: Minimum R-24 <br /> Step 4. Verify total window(including area of all foundation windows) Foundation Insulation: Minirnum R-10 <br /> And door area is equal or less than allowable percentage. ❑ Foundation windows: Yz"insulated glass,wood or vinyl frame <br /> TABLE FOR DETERMINIIYG MAXIMUM WINDOW A�VD DOOR AREA <br /> Maxiinuin Allowable Total Window and Door Area as <br /> a Percentage of Ex osed Wall 12% 14% 16% 18% 20% 22% 24% 26% 28% <br /> Wall T e (Standard Framin�): Maximum Avera e Window U-value(exce t foundation windows): <br /> ❑ 2x4, R-13 insulation, >_R-7 sheathing 0.55 0.47 0.41 0.36 0.33 0.30 0.27 0.25 0.23 <br /> ❑ 2x4, R-15 insulation, ? R-5 sheathing 0.52 0.45 0.39 0.35 0.31 0.28 0.26 0.24 0.22 <br /> 2x6,R-19 insulation,<R-5 sheathin� 0.48 0.41 0.36 0.32 0.29 0.26 0.24 0.22 0.21 <br /> ❑ 2x6, R-19 insulation,?R-5 sheathing 0.56 0.48 0.42 0.37 0.34 0.31 0.28 0.26 0.24 <br /> ❑ 2x6, R-21 insulation,<R-5 sheathin 0.51 0.43 038 0.34 0.30 0.28 0.25 0.23 0.22 <br /> ❑ 2x6, R-Zl insulation, >_R-5 sheathing 0.58 0.50 0.44 0.39 0.35 0.32 0.29 0.27 0.25 <br /> Wall T e (Advanced Framin ): Maximum Avera e Window U-value(exce t foundation windows): <br /> ❑ 2x6, R-19 insulation,<R-5 sheathin 0.52 0.45 0.39 0.3� 0.31 0.28 0.26 0.24 0.22 <br /> ❑ 2x6, R-19 insulation,>_ R-5 sheathing 0.58 0.50 0.44 0.39 0.35 0.32 0.29 0.27 0.25 <br /> ❑ 2x6, R-2l insulation,<R-5 sheathin; 0.55 0.47 0.41 0.36 0.33 0.30 0.27 0.?5 0.23 <br /> ❑ 2x6, R-?I insulation, >_ R-5 sheathing 0.60 0.52 0.46 0.41 0.36 0.33 0.30 0.28 0.26 <br /> __ _... ___ <br /> Window U-value: Source: '. ❑ NFRC ❑ ASHRAE 1993 Handbook ' <br /> ... � �.. ..... .� ... <br /> _ __ _... _._.... <br /> ��� X = - � ' _ ��' � °�n , < �� °/n ; <br /> window&door area gross exposed wall area DES[GN ALLOWABLE (from table above) <br /> MINNESOTA ENFRGY CODE WHICH RULES MAY I USE � <br /> TYPE OF RESIDENTIAL BUILDING APPLICABLE RULES <br /> Detached R-3 occupancy 1-and 2-family dwellings Chap[er 7672; or <br /> Exam les: sin le f'amil ,twin homes,du leYes Cha ter 7670"Cate�o 1" with statuto de ressurization and ventilation re uirements <br /> Attached R-3 occupancy dwellings Chapter 7674; or <br /> Exam fes: tri lex townhouses and row houscs Cha ter 7670 with either"Cate o 1" or `'Cate o 2" rovisions <br /> R-1 occupancy buildings of 3 stories or less Chapter 7674; or <br /> Exam les: condominiums or a amnents Cha ter 7670 with either"Cate o l" or "Cate o 2" rovisions <br /> R-1 occupancy buildings over 3 stories high Chapter 7676 <br /> Exam les: hi h rise condos or a artments <br /> �,..,:,��� <br />
The URL can be used to link to this page
Your browser does not support the video tag.