Laserfiche WebLink
LINE-HT.XLS Heat loss Master Residence <br /> Client Name: <br /> Site Address: <br /> � <br /> K�ITH WATERS & ASSOCIATES, INC. <br /> 10340 Viking Drivc Bden Prairic,MN 55344 Liccnsc 110001508 <br /> '�-���-� . Phonc(6l2)942-1060 I'aa(612)942-1058 <br /> Permitted Heat Loss <br /> Area(Sq. Ft.) x U Value = Heat Loss <br /> 1 Total exposed wall area: 6382.00 0.11 702.02 <br /> 2 Total roof/ceiling area: 3355.00 0.03 87.23 <br /> Total permitted heat loss: 789•25 <br /> Heat Loss Through Wall Segments <br /> Wall Windows 1446.50 0.31 448.41 <br /> Doors 55.56 0.19 10.56 <br /> Rim Joist 597.00 0.04 23.34 <br /> Wall Framing(Average 10%) 428.29 0.11 46.10 <br /> Net Insulated Wall 3854.65 0.04 159.75 <br /> Foundation Windows 0.00 0.00 0.00 <br /> Foundation Wall Above Grade 0.00 0.06 0.00 <br /> 3 Total heat loss through walls: 688.16 <br /> (If item#3 is the same as or less than item#1, <br /> then you have met the intent of SBC(c)2. <br /> Heat Loss Through Roof <br /> Skylight 48.00 0.34 16.32 <br /> Roof/Ceiling Framing(Average 10%) 330.70 0.03 9.41 <br /> Net Insulated Roof/Ceiling 2976.30 0.02 50.63 <br /> 4 Total heat loss through roof: 76.37 <br /> (If item#4 is the same as or less than item#2, <br /> then you have met the intent of SBC(c)2. <br /> Alternate Building Envelope Design <br /> To utilize the total envelope system method,the values established by the sum of items#3 and#4 <br /> shail not be greater than the sum of items#1 and#2. <br /> Permitted Loss Item 1 +Item 2: 702.02 87.23 789.25 <br /> Actual Loss Item 3+Item 4: 688.16 76.37 764.53 <br /> Heat loss is acceptable <br /> 11/9/95 1 <br />