My WebLink
|
Help
|
About
|
Sign Out
Home
Browse
Search
2015-00484 - new structure
Orono
>
Property Files
>
Street Address
>
F
>
Forest Arms Lane
>
945 Forest Arms Lane - 07-117-23-12-0019
>
Permits/Inspections
>
2015-00484 - new structure
Metadata
Thumbnails
Annotations
Entry Properties
Last modified
8/22/2023 5:30:36 PM
Creation date
9/26/2016 2:21:21 PM
Metadata
Fields
Template:
x Address Old
House Number
945
Street Name
Forest Arms
Street Type
Lane
Address
945 Forest Arms La
Document Type
Permits/Inspections
PIN
0711723120019
Supplemental fields
ProcessedPID
Updated
There are no annotations on this page.
Document management portal powered by Laserfiche WebLink 9 © 1998-2015
Laserfiche.
All rights reserved.
/
61
PDF
Print
Pages to print
Enter page numbers and/or page ranges separated by commas. For example, 1,3,5-12.
After downloading, print the document using a PDF reader (e.g. Adobe Reader).
View images
View plain text
Rhvac-Residential&Light Commerciai HVAC Loads � Elite Software Development,Inc. <br /> West Metro Mechanical Inc. Eaton 345 Forest Arms�ane,Orono,MN <br /> �NQrwood MN 5536$_ -- - ---------_. _Pag�_14: <br /> Detailed Room_Loads - Room 7 - Main (Average Load Procedure) <br /> _ _ -- _ _ <br /> _--_- __- __________ - - � <br /> �Generai <br /> t_.y <br /> Calculation Mode: Htg. &clg. Occurrences: 1 <br /> Room Length: 32.0 ft. System Number: 1 ' <br /> Room Width: 10.0 ft. Zone Number: 1 <br /> Area: 320.0 sq.ft. Supply Air: 260 CFM <br /> Ceiling Height: 9.0 ft. Supply Air Changes: 5.4 AC/hr <br /> Volume: 2,880.0 cu.ft. Req. Vent. Clg: 0 CFM , <br /> I Number of Registers: 3 Actual Winter Vent.: 18 CFM <br /> ' Runout Air: 87 CFM Percent of Supply.: 7 % <br /> � Runout Duct Size: 5 in. Actual Summer Vent.: 19 CFM <br /> Runout Air Velocity: 637 ft./min. Percent of Supply: 7 % <br /> ' Runout Air Velocity: 637 ft./min. Actual Winter Infil.: 15 CFM ' <br /> Actual Loss: 0.325 in.wg./100 ft. Actual Summer Infil. 8 CFM <br /> � _ __ ___ _ __ _ . _ <br /> Item Area -U- Htg Sen Clg �at Sen <br /> i Descripti_on _ _ Quanfi�_____ Value._ _,HTM_ __ Loss_ _ HTM Gain Gain <br /> _ _ _ _ _ __ <br /> N -Wall-12F-Osw 32 X 9 257.4 0.065 5.4 1,389 1.1 0 273 <br /> I W-Wall-12F-Osw 10 X 9 46.5 0.065 5.4 251 1.1 0 49 <br /> , E-Wall-12F-Osw 10 X 9 81.8 0.065 5.4 442 1.1 0 87 <br /> ' W-Gls-1 D-cv-o shgc-0.56 0%S (3) 43.5 0.570 47.3 2,058 61.4 0 2,673 <br /> N -Gls-1 D-cv-o shgc-0.56 100%S 12 0.570 47.3 567 19.8 0 237 <br /> (3) <br /> , N -Gls-1 D-cv-o shgc-0.56 100%S 18.6 0.570 47.3 880 19.7 0 367 <br /> E-Gis-1 D-cv-o shgc-0.56 0%S 8.2 0.570 47.3 386 61.4 0 501 <br /> UP-Ceil-16B-50 32 X 10 320 0.020 1.7 531 1.0 0 326 <br /> Subtotals for Structure: 6,504 0 4,513 <br /> Infil.: Win.: 14.9, Sum.: 7.9 468 2.829 1,324 0.286 156 134 <br /> AED Excursion: 911 , <br /> ' Room Totals: 7,828 156 5,558 <br /> i <br /> � <br /> . i <br /> � � <br /> C:\ ...\Eaton New Construction.rh9 Tuesday, April 21, 2015, 9:56 PM <br />
The URL can be used to link to this page
Your browser does not support the video tag.