My WebLink
|
Help
|
About
|
Sign Out
Home
Browse
Search
2015-00484 - new structure
Orono
>
Property Files
>
Street Address
>
F
>
Forest Arms Lane
>
945 Forest Arms Lane - 07-117-23-12-0019
>
Permits/Inspections
>
2015-00484 - new structure
Metadata
Thumbnails
Annotations
Entry Properties
Last modified
8/22/2023 5:30:36 PM
Creation date
9/26/2016 2:21:21 PM
Metadata
Fields
Template:
x Address Old
House Number
945
Street Name
Forest Arms
Street Type
Lane
Address
945 Forest Arms La
Document Type
Permits/Inspections
PIN
0711723120019
Supplemental fields
ProcessedPID
Updated
There are no annotations on this page.
Document management portal powered by Laserfiche WebLink 9 © 1998-2015
Laserfiche.
All rights reserved.
/
61
PDF
Print
Pages to print
Enter page numbers and/or page ranges separated by commas. For example, 1,3,5-12.
After downloading, print the document using a PDF reader (e.g. Adobe Reader).
View images
View plain text
_ ___ --. _ <br /> Rhvac-Residentiai&Light Commerciai HVAC Loads .N Elite Software Development,Inc. <br /> !West Metro Mechanical Inc. Eaton 345 Forest Arms Lane,Orono,MN <br /> I Norwood.�N_`.�53Sz�___------- --- - -- __ _ _ _ ----------__ _--P��Q <br /> __ _.. _. <br /> Detailed Room Loads - Room 3 - Main (Average Load Procedure) <br /> - _- _ _ -_- -__- ----_-- _ � � <br /> _ <br /> General � <br /> � --- a <br /> Calculation Mode: Htg. &clg. Occurrences: 1 <br /> Room Length: 32.0 ft. System Number: 1 <br /> Room Width: 167 ft. Zone Number: 1 ' <br /> ' Area: 533.3 sq.ft. Supply Air: 385 CFM <br /> , Ceiling Height: 9.0 ft. Supply Air Changes: 4.8 AC/hr <br /> ' Volume: 4,800.1 cu.ft. Req. Vent. Clg: 0 CFM <br /> � Number of Registers: 4 Actual Winter Vent.: 21 CFM <br /> ; Runout Air. 96 CFM Percent of Supply.: 6 % <br /> , Runout Duct Size: 6 in. Actual Summer Vent.: 28 CFM <br /> Runout Air Velocity: 491 ft./min. Percent of Supply: 7 % <br /> , Runout Air Velocity: 491 ftJmin. Actual Winter Infil.: 13 CFM <br /> Actual Loss: 0.151 in.wg./100 ft. Actual Summer Infil.: 7 CFM <br /> __ ____ __ <br /> _ _ <br /> _ __ <br /> . . .. __. _ <br /> ! Item Area -U- Htg Sen Clg Lat Sen <br /> 'De_scripti_on__ __ _ ___ Quantity Value HTM Loss_ HTM Gain Gain <br /> W-Wall-12F-Obw 16.7 X 9 100.6 0.065 5.4 543 0.8 0 76 <br /> I E-Wall-12F-Obw 16.7 X 9 125.5 0.065 5.4 677 0.8 0 95 ' <br /> ' S -Wall-12F-Obw 12 X 9 66 0.065 5.4 356 0.8 0 50 <br /> S-Gls-1D-cv-o shgc-0.56 0%S 42 0.570 47.3 1,987 34.6 0 1,454 <br /> W-Gls-1 D-cv-o shgc-0.56 0%S (2) 24.5 0.570 47.3 1,158 61.5 0 1,506 <br /> I W-Gls-1 D-cv-o shgc-0.56 0%S 24.9 0.570 47.3 1,180 61.5 0 1,533 <br /> ; E-Gls-1 D-cv-o shgc-0.56 0%S (3) 24.5 0.570 47.3 1,158 61.4 0 1,503 <br /> UP-Ceil-166-50 32 X 16.7 533.3 0.020 1 J 885 1.0 0 544 <br /> Subtotals for Structure: 7,944 0 6,761 <br /> Infil.: Win.: 13.0, Sum.: 6.9 408 2.828 1,154 0.287 136 117 <br /> , AED Excursion: 1,349 <br /> Room Totals: 9,098 136 8,227 <br /> I <br /> I <br /> � <br /> C:\...\Eaton New Construction.rh9 Tuesday, April 21, 2015, 9:56 PM <br />
The URL can be used to link to this page
Your browser does not support the video tag.