Laserfiche WebLink
�. . . . _ . _. ... . .. _--.. . . . -._--_-.__.. . <br /> I�b�pdRMN 5368�'�9ht Commercial HVAC Loads � Eaton 345 Fo efst Arm�s Lanle,Orono�,'MN <br /> -- -- ----_----__- __ _ _P�q�6_. <br /> Total Building Summary Loads <br /> _ -- - <br /> . ------------- <br /> . _-- _ __--- <br /> Component � . ,.<.`` Area Sen Lat Sen Total <br /> I Descri�tion __,------------- _..-- ----_ _ Quan _ _ Loss Gain Gain Gain '. <br /> 1 D-cv-o: Glazing-Double pane, operable window, clear, 48.3 2,288 0 1,740 1,740 <br /> vinyl frame, outdoor insect screen with 100% <br /> ; coverage, light color drapes with medium weave with <br /> ' 50% coverage, u-value 0.57, SHGC 0.56 <br /> i 1 D-cv-o: Glazing-Double pane, operable window, clear, 438.6 20,746 0 24,090 24,090 <br /> vinyl frame, u-value 0.57, SHGC 0.56 <br /> ' 11P: Door-Metal- Polyurethane Core 42 1,010 0 328 328 <br /> , 12F-Osw: Wall-Frame, R-21 insulation in 2 x 6 stud 1671 9,014 0 1,770 1,770 <br /> cavity, no board insulation, siding finish, wood studs <br /> 1560-10sf-2: Wall-Basement, , R-10 board insulation to 966.1 6,222 0 750 750 ' <br /> floor, no interior finish, 2'floor depth ' <br /> 12F-Obw:Wall-Frame, R-21 insulation in 2 x 6 stud 292.1 1,576 0 221 221 <br /> cavity, no board insulation, brick finish,wood studs <br /> ', 166-50: Roof/Ceiling-Under Attic with Insulation on Attic 2073.3 3,441 0 2,115 2,115 <br /> Floor(also use for Knee Walis and Partition <br /> Ceilings), Vented Attic, No Radiant Barrier, Dark <br /> Asphalt Shingles or Dark Metal, Tar and Gravel or <br /> Membrane, R-50 insulation <br /> 21 B-28: Floor-Basement, Concrete slab, any thickness, 2 1800 2,241 0 0 0 <br /> or more feet below grade, R-3 or higher insulation <br /> installed below floor, any floor cover, shortest side of <br /> , floor slab is 28'wide <br /> ' Subtotals for structure: 46,538 0 31,014 31,014 <br /> People: 0 0 0 0 <br /> Equipment: 0 0 0 <br /> Lighting: 0 0 0 ' <br /> Ductwork: 0 0 0 0 ' <br /> � Infiltration: Winter CFM: 103, Summer CFM: 54 9,113 1,073 925 1,998 <br /> � Ventilation:Winter CFM: 130, Summer CFM: 130 4,606 2,572 888 3,460 <br /> , Exhaust: Winter CFM: 130, Summer CFM: 130 <br /> AED Excursion: 0 0 6,263 6,263 <br /> Total Building Load Totals: 60,257 3,645 39,090 42,736 <br /> - ---- - - -, <br /> Check Figures -- ------------------ ----� <br /> Total Building Supply CFM: 1,790 CFM Per Square ft.: 0.462 <br /> Square ft. of Room Area: 3,873 Square ft. Per Ton: 1,088 <br /> Volume (ft') of Cond. Space: 34,860 <br /> -- --- _ <br /> __ ---- -- -- - <br /> -- - <br /> ' B ailding.Loads_- ____ -- <br /> __ .__ ----- --__ - --- ---- _ _ - <br /> ' Total Heating Required Including Ventilation Air: 60,257 Btuh 60.257 MBH <br /> Total Sensible Gain: 39,090 Btuh 91 % <br /> Total Latent Gain: 3,645 Btuh 9 % <br /> Total Cooling Required Including Ventilation Air: 42,736 Btuh 3.56 Tons (Based On Sensible+ Latent) <br /> _--- ____ <br /> _ __-- _ _----_ <br /> . ._--------_ <br /> Notes __ _ -- _ _ ---� . <br /> - ----._.____------- <br /> --- -- --- <br /> _ ___._ ._ --- - -------� <br /> Rhvac is an ACCA approved Manual J and Manual D computer program. ', <br /> , Calculations are performed per ACCA Manual J 8th Edition, Version 2, and ACCA Manual D. <br /> , All computed results are estimates as building use and weather may vary. <br /> ; Be sure to select a unit that meets both sensible and latent loads according to the manufacturer's performance data at <br /> your design conditions. <br /> C:\...\Eaton New Construction.rh9 Tuesday, April 21, 2015, 9:56 PM <br />