. __ <br /> Rhvac-Residential 8 Light Commercial HVAC Loads Elite Software Development,inc. <br /> West Metro Mechanical Inc. Eaton 345 Forest Arms Lane,Orono,MN <br /> Norwood,MN 55368 . _ _ _ Page6_ <br /> TotalBuilding Summary Loads <br /> _ _ - _ <br /> Component Area Sen lat Sen Tota( <br /> Description Quan Loss Gain Gain Gain <br /> - ---------- ---- _---- _ -- __ _ ---- <br /> 1D-cv-o: Giazing-Double pane, operablewindow, clear, 48.3 2,288 0 1,740 1,740 <br /> vinyl frame, outdoor insect screen with 100% <br /> coverage, light color drapes with medium weave with <br /> 50% coverage, u-value 0.57, SHGC 0.56 <br /> 1 D-cv-o: Glazing-Double pane, operable window, clear, 438.6 20,746 0 24,090 24,090 <br /> vinyl frame, u-value 0.57, SHGC 0.56 <br /> 11P: Door-Metal- Polyurethane Core 42 1,010 0 328 328 <br /> 12F-Osw: Wall-Frame, R-21 insulation in 2 x 6 stud 1671 9,014 0 1,770 1,770 <br /> cavity, no board insulation, siding finish, wood studs <br /> 1560-10sf-2: Wall-Basement, , R-10 board insulation to 966.1 6,222 0 750 750 <br /> floor, no interior finish, 2'floor depth <br /> 12F-Obw: Wall-Frame, R-21 insulation in 2 x 6 stud 292.1 1,576 0 221 221 <br /> cavity, no board insulation, brick finish, wood studs <br /> 16B-50: Roof/Ceiling-Under Attic with Insulation on Attic 2073.3 3,441 0 2,115 2,115 <br /> Floor(also use for Knee Walls and Partition <br /> Ceilings), Vented Attic, No Radiant Barrier, Dark <br /> Asphalt Shingles or Dark Metal, Tar and Gravel or <br /> Membrane, R-50 insulation <br /> 21 B-28: Floor-Basement, Concrete slab, any thickness, 2 1800 2,241 0 0 0 <br /> or more feet below grade, R-3 or higher insutation <br /> installed below floor, any floor cover, shortest side of <br /> floor slab is 28'wide <br /> Subtotals for structure: 46,538 0 31,014 31,014 <br /> People: 0 0 0 0 <br /> Equipment: 0 0 0 <br /> Lighting: 0 0 0 . <br /> Ductwork: 0 0 0 0 <br /> Infiltration: Winter CFM: 103, Summer CFM: 54 9,113 1,073 925 1,998 <br /> Ventilation: Winter CFM: 130, Summer CFM: 130 4,606 2,572 888 3,460 <br /> Exhaust: Winter CFM: 130, Summer CFM: 130 <br /> AED Excursion: 0 0 6,263 6,263 <br /> Total Building Load Totals: 60,257 3,645 39,090 42,736 <br /> - _ _ -__ <br /> - - __ - ------------ ---- <br /> Check Fi�ures _ _ _ - - - - <br /> -- - - --- ----- ---------- -- -------' <br /> Total Building Supply CFM: 1,790 CFM Per Square ft.: 0.462 <br /> Square ft. of Room Area: 3,873 Square ft. Per Ton: 1,088 <br /> Volume (ft3) of Cond. Space: 34,860 <br /> _ _ -- ----- -------- _- _ <br /> Buildin� Loads --------------------- <br /> _ _ ----- - - ------- ----:_� _-�_�_ <br /> Total Heating Required Including Ventilation Air: 60,257 Btuh 60.257 MBH �--iLL--�-_____-_____ <br /> Total Sensible Gain: 39,090 Btuh 91 % <br /> Total Latent Gain: 3,645 Btuh 9 % <br /> Total Cooling Required Including Ventilation Air: 42,736 Btuh 3.56 Tons(Based On Sensible+ Latent) <br /> ---_____------ ------________�__,_�--__ <br /> Notes -_ __- __ <br /> ___..- ------ ---_- _ _------------- ____---- ---- -=---------- ----- --__.� ------------ -------- <br /> Rhvac is an ACCA approved Manual J and Manual D computer program. <br /> Calculations are performed per ACCA Manual J 8th Edition, Version 2, and ACCA Manual D. <br /> All computed results are estimates as building use and weather may vary. <br /> Be sure to select a unit that meets both sensible and latent loads according to the manufacturer's performance data at <br /> your design conditions. <br /> I <br /> I <br /> C:1...\Eaton New Construction.rh9 Sunday, July 26, 2015, 9:30 PM <br />