My WebLink
|
Help
|
About
|
Sign Out
Home
Browse
Search
2015-00934 - mechanical
Orono
>
Property Files
>
Street Address
>
F
>
Forest Arms Lane
>
945 Forest Arms Lane - 07-117-23-12-0019
>
Permits/Inspections
>
2015-00934 - mechanical
Metadata
Thumbnails
Annotations
Entry Properties
Last modified
8/22/2023 5:30:37 PM
Creation date
9/26/2016 2:19:21 PM
Metadata
Fields
Template:
x Address Old
House Number
945
Street Name
Forest Arms
Street Type
Lane
Address
945 Forest Arms La
Document Type
Permits/Inspections
PIN
0711723120019
Supplemental fields
ProcessedPID
Updated
There are no annotations on this page.
Document management portal powered by Laserfiche WebLink 9 © 1998-2015
Laserfiche.
All rights reserved.
/
11
PDF
Print
Pages to print
Enter page numbers and/or page ranges separated by commas. For example, 1,3,5-12.
After downloading, print the document using a PDF reader (e.g. Adobe Reader).
View images
View plain text
�A � <br /> • _,_ _ -_ _ _ _ __ <br /> Rhvac-Residential&Light Commercial HVAC l.oads Elite Software Development,lnc. <br /> West Metro Mechanical Inc. Eaton 345 Forest Arms Lane,Orono, MN <br /> Norwood, MN 55368 page 2 <br /> Project Report <br /> _ ____- -- - _ _ - -- - -- — <br /> _ ------ <br /> General Project information `' " <br /> _---_ _ ------- --- — -- ------ ---- --- <br /> Project Title: Eaton 345 Forest Arms Lane, Orono, MN <br /> Designed By: Andrew Franck <br /> Project Date: Tuesday, April 21, 2015 <br /> _ - __ -- <br /> __ _ __ _ -__ _ - - <br /> Desi�n Data <br /> - -- _ __ -- - -_ _ __ --- - _ _ _ __ <br /> Reference City: Minneapolis/St. Paul AP, Minnesota <br /> Building Orientation: Front door faces East <br /> Daily Temperature Range: Medium <br /> Latitude: 44 Degrees <br /> Elevation: 834 ft. <br /> Altitude Factor: 0.970 <br /> Outdoor Outdoor Outdoor Indoor Indoor Grains <br /> DN Bulb Wet Bulb Rel.Hum Rel.Hum Dry Bulb Difference <br /> Winter: -11 -11.42 n/a n/a 72 n/a <br /> Summer: 88 71 44% 50% 72 30 <br /> __ -- ___ _ __ <br /> - - __ _ __ <br /> Check Figures _ <br /> _ __ _ _ _ . __-------- -- ----_. _ <br /> Total Building Supply CFM: 1,790 CFM Per Square ft.: 0.462 <br /> Square ft. of Room Area: 3,873 Square ft. Per Ton: 1,088 <br /> Volume (ft')of Cond. Space: 34,860 <br /> ----- - ----- <br /> -- - - -----__ ------ ---- <br /> -- __ <br /> Building Loads _ __-- ------- ..___ <br /> -- -- ----- _ _---- ---- --------- __ __ -- --- -- <br /> Total Heating Required Including Ventilation Air: 60,257 Btuh 60.257 MBH <br /> Total Sensible Gain: 39,090 Btuh 91 % <br /> Total Latent Gain: 3,645 Btuh 9 % <br /> Total Cooling Required Including Ventilation Air: 42,736 Btuh 3.56 Tons (Based On Sensible + Latent) <br /> Notes _ _ _ _ . _ _ ___ ----- --_---------- _ .___ __ <br /> Rhvac is an ACCA approved Manual J and Manual D computer program. <br /> --- ---- ----------- — ------ -- <br /> Calculations are performed per ACCA Manual J 8th Edition, Version 2, and ACCA Manual D. <br /> All computed results are estimates as building use and weather may vary. <br /> Be sure to select a unit that meets both sensible and latent loads according to the manufacturer's performance data at <br /> your design conditions. <br /> C:\...\Eaton New Construction.rh9 Sunday, July 26, 2015, 9:30 PM <br />
The URL can be used to link to this page
Your browser does not support the video tag.