Laserfiche WebLink
Wall framing by others Sill plate by others w/1l2" <br /> diameter anchor bolts wl 7" <br /> minimum embed&standard <br /> washers @ 72"o.c.max or <br /> ,,�� equivalent metal strap <br /> anchors <br /> Maximum stem height is 12" <br /> (width to match sill plate) <br /> 6"Min <br /> 6"minimum thick cast-in- <br /> place concrete wall w/ �,� <br /> optional slab ledge (1)#4 continuous horizontal <br /> bar wlin 18"of top of wall <br /> Provide frost protection per <br /> Code <br /> #4 x 2'-0"long dowels @ 72" <br /> o.c. max w/5"minimum embed <br /> (dowels are not required if wali 8"minimum thick <br /> is backfilled in equal unreinforced concrete strip <br /> alternating lifts not exceeding � footing,required width to be <br /> 24"in height) determined per Code by <br /> others <br /> WALKOIJT/ SLAB-ON-GRADE FROST WALL DETAIL <br /> Note: Maximum unbalanced fill height may be up to 36"provided the wall is at least 8"thick <br /> Oswell Engineering and Consulting,L.L.C. 1901 E Hennepin Ave,#2(F1 a,•� �' �':�. <br /> Project Name: 2013 Standardized Concrete Foundation Drawings Minneapolis,MN 55413 �= <br /> � <br /> Description: Frost Wall Detail Phone:612-720-4fr39 ` <br /> , � <br /> Project# 12.100 Fax:612-886-2966 <br /> Client Name: Oscarson Masonry,LLC www.oswellec.cam <br /> Client Address: 12450 Count Road 32,Waconia,MN 55387 Page S4 of S6 ` •' <br /> . <br /> 12/3/2012 <br />