My WebLink
|
Help
|
About
|
Sign Out
Home
Browse
Search
re retaining wall
Orono
>
Property Files
>
Street Address
>
F
>
Forest Arms Lane
>
945 Forest Arms Lane - 07-117-23-12-0019
>
Correspondence
>
re retaining wall
Metadata
Thumbnails
Annotations
Entry Properties
Last modified
8/22/2023 5:30:38 PM
Creation date
9/26/2016 1:31:52 PM
Metadata
Fields
Template:
x Address Old
House Number
945
Street Name
Forest Arms
Street Type
Lane
Address
945 Forest Arms La
Document Type
Correspondence
PIN
0711723120019
Supplemental fields
ProcessedPID
Updated
There are no annotations on this page.
Document management portal powered by Laserfiche WebLink 9 © 1998-2015
Laserfiche.
All rights reserved.
/
10
PDF
Print
Pages to print
Enter page numbers and/or page ranges separated by commas. For example, 1,3,5-12.
After downloading, print the document using a PDF reader (e.g. Adobe Reader).
View images
View plain text
enera o es: <br /> 1. Wall thicknesses noted are nominal unless specifically stated otherwise. Maximum tolerance is 112". <br /> 2. Maximum wall to footing centerline offset is 2". A minimum of 2"of footing is to extend on each side of the wall. <br /> 3. Place matching hooks around all wall corners and intersections for each horizontal bar. <br /> 4. Horizontal bars may be placed anywhere within the wall thickness provided 2"minimum cover is provided. <br /> 5. Bar laps when required are to be at least 32 diameters for grade 40 bars and 48 diameters for grade 60 bars. <br /> 6. Allowable bar placement tolerance is 112". Tying is not required if tolerances are met and maintained. <br /> 7. Dowels may be drilled and installed after footing pour unless otherwise noted. Vertical bars may be embedded <br /> into footing in place of dowels at the same embedment. Vertical bars and dowels do not need to align. Dowels <br /> may be bent down for safety and covering then bent back before wall placement. <br /> 8. Sill plate sections require at least two anchors with one within 4"to 12"of each end and at all corners and <br /> intersections. Walls less than 24" in length require only one anchor. <br /> 9. Anchor bolts 1/2"or larger in diameter do not require corrosion protection per IRC section R319.3 exception 1. <br /> 10. Anchor bolts may be substituted with 1l2"diameter threaded rod epoxy grouted at same spacing with 7"embed. <br /> 11. The presence of form oil on the reinforcing is acceptable for the conditions contained in these drawings. <br /> 12. Slope grade 6"minimum downward away from foundations within first 10 feet or provide Code adequate swale. <br /> 13. Do not backfill until the concrete has reached at least 70 percent of the 28 day concrete strength. Use of <br /> adequate shoring is required when the final floor and slab systems are not in place. <br /> Cold Weather Guidelines: <br /> The following information is considered to be general guidelines for the placement of concrete in cold weather <br /> conditions. It is the contractor's responsibility to ensure proper means and methods are followed and that the final <br /> in place product is adequate. <br /> 1. The contractor is to work with the concrete supplier to obtain a mix design which accounts for the conditions <br /> expected. Use of extra cement, early-strength concrete,and accelerators are recommended at temperatures <br /> below 20 degrees F. <br /> 2. Concrete is to be delivered to the site in a timely manner. <br /> 3. Placement of concrete earlier in the day to take advantage of latent heat of sunlight is adviced. <br /> 4. Do not add additional water. Using water-reducing admixtures is recommended when required. <br /> 5. Forms are to be free of snow and ice. Do not place concrete in contact with frozen ground ,snow,or ice. <br /> 6. Preheating of rebar is not required, however it is to be free of frost, snow,and ice. <br /> 7. Use of form blankets or other approved protection is highly recommended for the top of the wall at temperatures <br /> below 10 de rees F and for the whole wall when below zero degrees F. <br /> Oswell EnglneeNng anci Consulting, L.L.C. 1901 E Hennepin Ave,#201 j,��,•�` `;��:'ry} r . <br /> Project Name: 2013 Standardized Concrete Foundation Drawings Minne�polis, MfV 55413 �-, '� <br /> Description: General Notes Phone:612-720-4639 • 1� <br /> Project# 12.100 Fax:612-886-2966 �� } <br /> Client Name: Oscarson Masonry, LLC www.oswelleacom `�"• '� <br /> Client Address: 12450 Count Road 32,Waconia, MN 55387 Page S2 of S6 t �`�- • - i <br /> 12/3/2012 <br />
The URL can be used to link to this page
Your browser does not support the video tag.