Laserfiche WebLink
Document management portal powered by Laserfiche WebLink 9 © 1998-2015 Laserfiche. All rights reserved.
Exhibit C <br /> �� <br /> � <br /> �� /� <br /> ���. o/� � �' �7 �Zi12F'Ptlil%' � G�''' �.J�C�C�I,Gr��J�, �_�2G. <br /> � � � �� <br /> ��� <br /> / 1___.-: �,:-...;__ 350 Hwy. 10 South, Suitc 101, St. Cloud, MI�T 56304 <br /> --- _: - _- 5 <br /> (320) 259-65?5 • Fax: (320) 259-6991 • www.duffyeng.com Q � <br /> t7 � � <br /> May 12, 2009 <br /> Coldwell Banker Burnet <br /> Attn: Dexter Andrews <br /> 201 East Lake Street <br /> Wayzata, MN 55391 <br /> Project: 1105 Ferndale Road, Orono, MN <br /> Re: Proposed demofition of existing house and rebuild on existing foundation. <br /> Dear Dexter: <br /> 1 �nspect2d the abov� pro�erty tin January 7, 2�05 to determine if the existing foundation and walls <br /> can supp�rt a new siructure a�t�r re�noving the �xistir�g resider�ce. ! also reviewed the p4.ans <br /> provid�d by Au#umn Design (datec� 11/2j108). The existing construction of the property is a singie <br /> slory wflod f:rar�ed hause �rith masanry (concrete bloek) wall craw! space faundatior�. Tf�� existing <br /> founda#ion is suitab9e fflr su�part af the new praposed two-siory I�o�se. Tt�e new structure shauld <br /> tiave an int�rior be�m iine to suRport the main flaor with tfie exteriar walls used to supporl the <br /> second floor and roof framing. The existing foundation walls should be repointed 'sn areas where <br /> cracking has occurred and stair step cracking areas shall be reinforced with #5 dowels grouted into <br /> vertical cores at the crack in the south-each corner and any other areas of stepping cracks of the <br /> wall. Please provide the proposed plans (including floor and roof truss shop drawings) so I can size <br /> the interior footings to minimize differential movement between the new footings and existing <br /> foundation. <br /> The plans I reviewed from Autumn Design show new foundation for the porch on the west end of the <br /> building. In this area there is a perimeter foundation wall in place. It is my recommendation to use <br /> the existing foundation and add interior footings as needed to support the floor instead of providing <br /> new piers and footings as shown on the current plan. <br /> On May 8, 2009 I was informed that the main floor level will have to raise 2.6' per the city of Orono. <br /> The existing foundation is sufficient to support this change. This would be best accomplished by <br /> adding 3 courses of concrete block to the top of the existing wall. <br /> Please feel free to share this letter with the local building officiaf and builder as required. You may <br /> contact me at (320) 259-6575 if you have any further questions or comments regarding this matter. <br /> Sin y <br /> yan• eavert, P.E. I hereby certifY that this plan,specification or report was prepared <br /> _ Project Engineer, Duffy Engineering & Associates, I(lC. by me or under my direct supervision and that I am a duly licenscd <br /> P�yCes�i�.m��l'�i�{��r u der Ihe laws of the State of Minnesota. <br /> r <br /> �t/J'�'--, <br /> f ��"'�.� <br /> �, r <br /> 'Fiyai ,Seaveit,P.E. <br /> 5/12/2009 No.41971 <br />