My WebLink
|
Help
|
About
|
Sign Out
Home
Browse
Search
2006-P10431 - mechanical
Orono
>
Property Files
>
Street Address
>
F
>
Ferndale Road West
>
905 Ferndale Road West - 02-117-23-44-0032 - New PID
>
905 Ferndale Rd W - 02-117-23-44-0010/9 - Old PID
>
Permis/Inspections
>
2006-P10431 - mechanical
Metadata
Thumbnails
Annotations
Entry Properties
Last modified
8/22/2023 4:11:16 PM
Creation date
9/8/2016 2:05:29 PM
Metadata
Fields
Template:
x Address Old
House Number
905
Street Name
Ferndale
Street Type
Road
Street Direction
West
Address
905 Ferndale Rd W
PIN
0211723440032
Supplemental fields
ProcessedPID
Updated
There are no annotations on this page.
Document management portal powered by Laserfiche WebLink 9 © 1998-2015
Laserfiche.
All rights reserved.
/
6
PDF
Print
Pages to print
Enter page numbers and/or page ranges separated by commas. For example, 1,3,5-12.
After downloading, print the document using a PDF reader (e.g. Adobe Reader).
View images
View plain text
�; <br /> i f,Rh.vac-Residential 8�Light Commercial HVAC Loads EI'rte Software Development,Inc. <br /> s ; ;Vogt Heating and Air Brooks Boathouse <br /> � � Minneapolis,MN 55426 Pa e 2 <br /> -- ---- -- - --_ - - - ----- - — ---- — <br /> R�diant Floor Report <br /> �--- -- - — --- ------ —_Tubing—=_Tubing Floor Supple- ' <br /> Radiant Floor Sens. Length Length Heat mental <br /> Room Description Room Heat To Meet To Fill Output Heat <br /> I Name [Heat Output,Spacing] Area Loss Load Room Btuh Req'd , <br /> 1-Main Level In-floor slab on grade[40,4J 352 13,875 1,041 946 12,619 1,256 I <br /> I System 1 Total: 352 13,875 1,041 946 12,619 1,256 <br /> Notes ------ - --- <br /> Area values shown include only those rooms for which radiant floor properties have been entered. <br /> I <br /> I <br /> � Sensible heat loss values on this report do not include losses associated with ductwork, ventilation, winter humidification or � <br /> � hot water piping. � <br /> I Tubing lengths include only the tubing that is part of the radiant floor panel itself and not the supply and return piping to <br /> and from the manifold. Tubing lengths are calculated from the Tubing Spacing input and an assumed installed coverage <br /> area that is based on a 6-inch offset from each wall around the perimeter of a rectangular room. � <br /> The Floor Heat Output Btuh values shown are calculated with the assumption that the tubing is installed to fifl the room at j <br /> the given spacing. I <br /> If the Supplemental Heat Required is negative, the radiant floor output exceeds the sensible loss of tf�e room by the <br /> indicated amount, assuming that the tubing is installed to fill the room at the given spacing. <br /> I , <br />
The URL can be used to link to this page
Your browser does not support the video tag.