�; <br /> i f,Rh.vac-Residential 8�Light Commercial HVAC Loads EI'rte Software Development,Inc. <br /> s ; ;Vogt Heating and Air Brooks Boathouse <br /> � � Minneapolis,MN 55426 Pa e 2 <br /> -- ---- -- - --_ - - - ----- - — ---- — <br /> R�diant Floor Report <br /> �--- -- - — --- ------ —_Tubing—=_Tubing Floor Supple- ' <br /> Radiant Floor Sens. Length Length Heat mental <br /> Room Description Room Heat To Meet To Fill Output Heat <br /> I Name [Heat Output,Spacing] Area Loss Load Room Btuh Req'd , <br /> 1-Main Level In-floor slab on grade[40,4J 352 13,875 1,041 946 12,619 1,256 I <br /> I System 1 Total: 352 13,875 1,041 946 12,619 1,256 <br /> Notes ------ - --- <br /> Area values shown include only those rooms for which radiant floor properties have been entered. <br /> I <br /> I <br /> � Sensible heat loss values on this report do not include losses associated with ductwork, ventilation, winter humidification or � <br /> � hot water piping. � <br /> I Tubing lengths include only the tubing that is part of the radiant floor panel itself and not the supply and return piping to <br /> and from the manifold. Tubing lengths are calculated from the Tubing Spacing input and an assumed installed coverage <br /> area that is based on a 6-inch offset from each wall around the perimeter of a rectangular room. � <br /> The Floor Heat Output Btuh values shown are calculated with the assumption that the tubing is installed to fifl the room at j <br /> the given spacing. I <br /> If the Supplemental Heat Required is negative, the radiant floor output exceeds the sensible loss of tf�e room by the <br /> indicated amount, assuming that the tubing is installed to fill the room at the given spacing. <br /> I , <br />