AuthantlslgnlD:d53CO2A8•FAE1-43CC•931A-�7JBOSB07FB2 , • <br /> €,JNIVERSITY Septic System Management Plar1 '''� _� � <br /> for Above Grade Systems <br /> OF MINNESOTA <br /> �_�.�. <br /> Professional Management Tasks <br /> These are the operation and mainlenance activities that a psonper/marntainer performs to help enswe <br /> long-term perfor►nance of yow system. Prafessionals should refer to the O/M Manuat for detailed <br /> checklists for tan�Es,pumps,alarms and other coraponents. Ca11800-321-864Z far more details. <br /> • Written record provided to homeowner after each visit. <br /> Plumbing/Soarce of Wastewater <br /> • Review the Water Use Appliance Chart on Page 5 with homeowner. Discuss sny changes in <br /> water use and the impact those changes may have an the septic system. <br /> • Review water usage rates(if available)with homeowner. <br /> Septic Tanlc/Pnmp Tanks <br /> • Manhole lid. A riser is recommended if the lid is not accessible from the ground surface.Insulate <br /> the riser cover for frost protection. <br /> • Liquid level.Check to make sure the tanlc is not lea3cing.The liquid level shoufd be level with the <br /> bottom of the outlet pipe.(If the water level is below the bottom of the outlet pipe, the tank may <br /> not be watertight If the water level is higher than the bottom of the outlet pipe of ihe tank, tEie <br /> ef�luent screen may need cleaning,or there may be ponding in the drainfield_) <br /> • brspection prpes.Replace damaged caps. <br /> . Ba„B`les. Check to make sure they are in place and attached, and that inledoutlet baffles are clear <br /> of buildup or obstrucrions. <br /> • E.,Biuent screen. Check to make sure it is in place; clean per manufacturer recommendation. <br /> Recommend retrofitted installation if one is not present. <br /> • Alarm.Verify that the alarm works. <br /> • Scum and sludge. Measure scum and sludge in each compartment of each septic and pump tank, <br /> pump if needed. <br /> Pump <br /> . Pump and controls. Check to make sure the pump and controls are operating correcdy. <br /> • Pwnp vault Check to mske sure it is in place;clean per manufacturer recommendations. <br /> • Alarm, Verify that the alarm works. <br /> • Drainback. Check to make siue it is operating proparly. <br /> • Event co�orter or run time. Check to see if there is an event counter or run time log for the pump. <br /> If there is one, calculate the water usage rate and compare to ttte anricipated average daily flow <br /> listed on Page 2. <br /> Soil Treatment Area <br /> • Inspection pipes.Check to make sure they are properly capped.Replace caps that are damaged. <br /> � Surfacing of e,�luent. Check for surfaced eftluent or other signs of problems. <br /> • Lateral flushing.Check lateral distribution;if cleanouts exist,flush and clean as needed. <br /> • Ponding, Check for ponding. Excessive ponding in at-grade and mound beds indicates <br /> problems, <br /> All other compoaents—inapect as listed here: <br /> _ __ --_.. <br /> Owner to call the City every �2 months for�rst 3 years of use for wetness or system <br /> wili be non-compfiant <br /> -�- <br />