My WebLink
|
Help
|
About
|
Sign Out
Home
Browse
Search
2004-P07940 - new septic system
Orono
>
Property Files
>
Street Address
>
F
>
Ferndale Road North
>
785 Ferndale Road North - 36-118-23-11-0012
>
Septic
>
2004-P07940 - new septic system
Metadata
Thumbnails
Annotations
Entry Properties
Last modified
8/22/2023 5:00:27 PM
Creation date
9/7/2016 11:50:03 AM
Metadata
Fields
Template:
x Address Old
House Number
785
Street Name
Ferndale
Street Type
Road
Street Direction
North
Address
785 Ferndale Road North
Document Type
Septic
PIN
3611823110012
Supplemental fields
ProcessedPID
Updated
There are no annotations on this page.
Document management portal powered by Laserfiche WebLink 9 © 1998-2015
Laserfiche.
All rights reserved.
/
22
PDF
Print
Pages to print
Enter page numbers and/or page ranges separated by commas. For example, 1,3,5-12.
After downloading, print the document using a PDF reader (e.g. Adobe Reader).
View images
View plain text
t <br /> ��P TESTl11►G� IIYC. Steven B. Schirmers � MPCACert.No. 627 <br /> 951 Katydid Lane NE • St. Michael, MN 55376 • (763) 497-3566 <br /> FAX (763)-497-5011 <br /> State License #394 <br /> ,. <br /> August 3, 2004 <br /> Tom & Michelle Cullum <br /> 785 No. Ferndale Rd. <br /> Orono, Henn. Co., MN <br /> This site has an existing on-site sewage treatment system which is surFace discharging. <br /> The system is classified as an imminent health hazard which must be repaired or <br /> disconnected within 10 months or as determined by the City of Orono. The existing <br /> tanks are deep & will need to be abandoned, pumped & filled with soil. <br /> This on-site sewage treatment system is designed for a Type 1, five bedroom home, in <br /> accordance with the Minnesota Pollution Control Agency Chapter 7080 and local <br /> ordinances. <br /> The soils on this site are clay loam. The seasonally saturated soils were located at 24" <br /> to 32" (mottled soil). Due to the seasonally saturated soils, a Pressurized Mound <br /> System will need to be installed to treat septic effluent. The bottom of the rock must be <br /> located at least 3' above the saturated soils. <br /> The soils at a depth of 12" have a percolation rate of 8.9 mpi. <br /> A pumping chamber will need to be installed to lift the effluent to the treatment area. <br /> The power supply and switches must be located outside the manhole and pumping <br /> chamber in a weather proof enclosure. A warning device must be installed with a light <br /> and sound device, this is in case of a pump failure. <br /> 1 <br />
The URL can be used to link to this page
Your browser does not support the video tag.