2 � <br /> RIGHT-J LOAD AND EQUIPMENT SUMMARY <br /> 5-28-98 <br /> For: TAPANI <br /> � O I /�f• �P/'.�i��ci �C� /�(� <br /> By: CONWAY MECHANICAL <br /> Job # . <br /> Wthr : Minneapolis/St . Paul AP MN <br /> Zone . <br /> WINTER DESIGN CONDITIONS SUMMER DESIGN CONDITIONS <br /> Outside db : -12 Deg F Outside db: 90 Deg F <br /> Inside db : 70 Deg F Inside db: 70 Deg F <br /> Design TD : 82 Deg F Design TD: 20 Deg F <br /> Daily Range M <br /> Rel . Hum. . 50 % <br /> Grains Water 33 gr <br /> HEATING SUMMARY SENSIBLE COOLING EQUIP LOAD SIZING <br /> Bldg. Heat Loss 155027 Btuh Structure 73507 Btuh <br /> Ventilation Air 400 CFM Ventilation 4400 Btuh <br /> Vent Air Loss 36080 Btuh Design Temp. Swing 3 . 0 Deg F <br /> Design Heat Load 191107 Btuh Use Mfg. Data n <br /> Rate/Swing Mult . 0 . 95 <br /> Total Sens Equip Load 74011 Btuh <br /> INFILTRATION LATENT COOLING EQUIP LOAD SIZING <br /> Const Qual b # Fireplaces 4 Internal Gains 2760 Btuh <br /> Ventilation 4488 Btuh <br /> HEATING COOLING Infiltration 7204 Btuh <br /> Area (sq. ft . ) 7510 9732 Tot Latent Equip Load 14452 Btuh <br /> Volume (cu. ft . ) 73893 96113 <br /> Air Changes/Hour 0 . 7 0 . 2 Total Equip Load 88463 Btuh <br /> Equivalent CFM 864 321 <br /> HEATING EQUIPMENT SUMMARY COOLING EQUIPMENT SUMMARY <br /> Make Make <br /> Model Model <br /> Type Type <br /> Efficiency / HSPF 0 . 0 COP/EER/SEER 0 . 0 <br /> Heating Input 2,�,0000 Btuh Sensible Cooling 0 Btuh <br /> Heating Output 204600 Btuh Latent Cooling 0 Btuh <br /> Heating Temp Rise 66 Deg F Total Cooling 0 Btuh <br /> Actual Heating Fan 2800 CFM Actual Cooling Fan 4000 CFM <br /> Htg Air Flow Factor 0 . 018 CFM/Btuh Clg Air Flow Factor 0 . 054 CFM/Btuh <br /> Space Thermostat Load Sens Heat Ratio 88 <br />