& Glass b 0 . 0 ** 0 0 **** 0 0 **** <br /> Doors Htg. C 0 . 0 ** 0 0 **** 0 0 **** <br /> d 0 . 0 ** 0 0 **** 0 0 **** <br /> e 0 . 0 ** 0 0 **** 0 0 **** <br /> f 0 . 0 ** 0 0 **** 0 0 **** <br /> - - - ------- -- -- -- ----- ----- ----- ---------- -- - - ------ -------------------- - <br /> 7 Windows North 19 . 0 0 **** 0 0 **** 0 <br /> & Glass NE&NW 45 . 0 0 **** 0 0 **** 0 <br /> Doors Clg . E&W 64 . 0 0 **** 0 0 **** 0 <br /> SE&SW 55 . 0 0 **** 0 0 **** 0 <br /> South 32 . 0 20 **** 640 0 **** 0 <br /> Horz 0 . 0 0 **** 0 0 **** 0 <br /> - - - - ----- - -- -- --- -- -------- ---- ---------- ---------- -------------- ------ - <br /> 8 Othr doors b lOFI20 . 0 0 . 0 0 0 0 0 OI 0 <br /> 9 Net a 12H 4 . 9 1 .4 170 836 241 0 0 0 <br /> Exposed b 15C 4 . 2 0 . 0 0 0 0 0 0 0 <br /> Walls and c 15F 4 . 8 0 . 0 0 0 0 0 0 0 <br /> Partitions d 0 . 0 0 . 0 0 0 0 0 0 0 <br /> e 0 . 0 0 . 0 0 0 0 0 0 0 <br /> f 0 . 0 0 . 0 0 0 0 0 0 0 <br /> 10 Ceilings a 16I 1 . 9 0 . 8 144 272 119 0 0 0 <br /> b 18B 5 . 9 2 . 6 0 0 0 0 0 0 <br /> c 0 . 0 0 . 0 0 0 0 0 0 0 <br /> - - - - - ----- -- -- --- -- -- ------ - --- --------- - -- -------- -------- ----- - -- ---- - <br /> 11 Floors a 21A 2 . 0 0 . 0 0 0 0 0 0 0 <br /> b 20J 2 . 9 0 . 5 0 0 0 0 0 0 <br /> c 19J 1 . 4 0 . 0 0 0 0 0 0 0 <br /> ------ ----- -- -- --- ----- -------- -------------------- - ------------------- - <br /> 12I Infiltration b I95 . 3I 7 . 0 20I 1905I 140 OI OI 0 <br /> -- ------ - ----- ----------------- -------------------- -------------------- - <br /> 13 Subtot Btuh Loss=6+8 . . +11+12 **** 3605 **** **** 0 **** <br /> 14 Duct Btuh Loss 0% 0 **** 0% 0 **** <br /> 15 Total Btuh Loss = 13+14 **** 3605 **** **** 0 **** <br /> ------------- -- --- -- --- -- ----- - -- ----- ------------- - ------------------- - <br /> 16 Int . Gains : People @ 300 0 **** 0 0 **** 0 <br /> Appl . @ 1200 0 **** 0 0 **** 0 <br /> 17 Subtot RSH Gain=7+8 . . +12+16 **** **** 1140 **** **** 0 <br /> 18 Duct Btuh Gain 0% **** 0 0% **** 0 <br /> 19 Total RSH Gain = 17+18 **** **** 1140 **** **** 0 <br /> 20 CFM Air Required **** 65 62 **** 0 0 <br /> --- Printout certified by ACCA to meet all requirements of Manual Form J --- <br /> � Job # : Zone : <br /> ----- MANUAL J: 7th Ed. ---- RIGHT-J: V1 . 67 ---- TR1524 -------------- --- <br /> 1 Name of Room SARAHS BEDROOM STORAGE <br /> 2 Running Ft . Exposed Wall 18 . 0 Ft . 17 . 0 Ft . <br /> 3 Room Dimensions, Ft . 24 . 0 x 13 . 0 Ft . 25 . 0 x 11 . 0 Ft . <br /> 4 Ceiings, Ft I Condit . Option 9 . 0 � heat/cool 8 . 0 I heat/cool <br /> ------- - ---- -- ---- --- --- - ---------------------- ----- -- ------------------ - <br /> TYPE OF CST HTM Area Btuh Area Btuh <br /> EXPOSURE NO. Htg IClg Length Htg I Clg Length Htg � Clg L <br /> -------- ---- -- -- --- -- --- ---------------------------- -------------------- - <br /> 5 Gross a 12H 4 . 9 1 . 4 162 **** **** 136 **** **** <br /> ExpOsed b 15C 4 . 2 0 . 0 0 **** **** 0 **** **** <br />