Laserfiche WebLink
� °� <br /> o:�:: o <br /> ,��� - C ITY of ORUNO <br /> � �;b��''���'�-� , �► <br /> r�„ ��� a� ��,. �:~ !� Municipal Offices <br /> 'CA i��'';�;���I'�,���f,.� �,�'� <br /> � ,�9 '�,,,. t,�� . 4,�/ Street Address: Mailmg Address: <br /> kEBH� � 2750 Kelley Parkway P.O. Boz 66 <br /> Orono, MN 55356 Crystal Bay, MN 55323-0066 <br /> To Current Owner: Address: �j S }��^�`j�<- ��- N� <br /> City Ordinance 199 requires that each existing on-site sewage treatment system in Orono be inspected every two years. <br /> The on-site sewage treatment system at the above address has been inspected and appears to fall into the categories checked below. <br /> S STEM CONFORMITY 1-3 : � <br /> 1 "CODE SYSTEM" An ISTS which meets all the location,design and construction standards ofthe currentOrono Municipal Code. <br /> 2 "COMPLIANT SYSTEM" An ISTS which does not meet all the location,design and construction standards of the cunent Orono Municipal <br /> Code but does meet the three foot separation requirement or two foot requirement for systems installed 1996 or earlier,and which is not failing or <br /> an imminent threat to public health or safety. <br /> 3 "NON-COMPLIANT SYSTEM" A prohibited ISTS;an ISTS located within a designated 100-yeaz flood plain,any ISTS which may <br /> or may not meet all the location,design,or constniction standards of the current Orono Municipal Code and which is failing for any reason;and <br /> any ISTS with less than three feet of unsaturated soil or sand between the distribution device and the(imiting soil characteristics. <br /> TANK CONDITION l5-7): � <br /> Tank inspection indicates: <br /> 5 Pumpout not needed at this time. <br /> USeptic tanks must be pumped out this year (city code requires tanks to be pumped out once every 3 years. <br /> Tank was last pumped �0 'i-�'`11-- ). <br /> Make sure septic tanks are pumped through manhole and not through white inspection pipes, This allows for the <br /> proper cleanin�. Keep water softner and iron filter discharge out of septic svstem. <br /> 7 Inspection risers missing-tanks could not be inspected. Inspection risers(4" dia.pipe)must be installed in each tank. If <br /> tanks have not been pumped out within the last three years,they should be pumped out now. <br /> � <br /> ��FIELD CONDITION(8-10): _� <br /> �JDramfield is dry,no surfacing evident. <br /> 9 Some evidence of surfacing,not critical yet. <br /> 10 Drainfield is saturated and visibly discharging untreated effluent to the surface. Contact the City Inspector <br /> immediately. Repairs must be completed within 90 days. <br /> COMMENTS: ���r�=�.�.C1� ` a�j�� �(C__ �c1N.� .St,� t;� f-r�lC� <br /> SL ^��,— �;�y <br /> � � ���� ��� ��� <br /> Date of Inspection Matt Bolterman - Septic System Inspector <br /> Note: In the event that this inspection report is used to satisfy the requirements for a mortgage or other Vansfer of property,be advised that this report does not guazantee <br /> or certify that an existing system will continue to function properly,but is merely an opinion ofthe adequacy ofthe system under current conditions based on the available <br /> information. <br /> Telephone(952)249-4600 • �ax(952)249-4616 <br /> wvav ri mm�m m�nc <br />