Laserfiche WebLink
15-3763 <br /> June 16,2016 <br /> Page 7 of 8 <br /> existing homes on the properties being developed, payment of the standard Park Dedication fee <br /> for 3 new building lots would be appropriate; the current fee is $5,550 per lot or a total of <br /> $16,650. <br /> Stormwater and Drainage Improvements <br /> Applicant's revised plat with narrow private driveways is apparently intended in part to <br /> minimize disturbance and avoid the need for stormwater ponding. As proposed, stormwater <br /> management is being provided by individual rain gardens. It is likely that creating conforming <br /> roads with conforming cul-de-sacs will trigger the need for more aggressive stormwater <br /> management measures. <br /> Based on the provisions of Section82-284(1) with the existing home at 350 Stubbs Bay Road <br /> potentially remaining, the subdivision will be subject to the Stormwater and Drainage Trunk Fee <br /> for a total of 4 lots, resulting in a fee of 4 lots @ $7680/lot=$30,720. <br /> The stormwater management system for the current layout has been reviewed by the City <br /> Engineer (see Exhibit C for additional comments regarding stormwater management). All <br /> stormwater management shall be subject to MCWD requirements and approvals. <br /> Septic Systems & Wells <br /> The properties will be served by private on-site septic systems and private wells. Full soil testing <br /> and preliminary system designs have been completed for 5-bedroom homes. Testing and <br /> preliminary designs were completed with the original preliminary plat review, and those sites <br /> remain viable for future use. However, the previously tested and approved sites in the area of <br /> Lot 3 are not depicted on the submitted plans, and those sites would be almost completely within <br /> the proposed wetland buffer in Lot 3. <br /> Wetlands on Site and/or Impacted <br /> The wetland boundary delineation report has been approved by the MC WD. No wetlands are <br /> proposed to filled. A wide variation in wetland buffer widths is proposed, with lots 2 and 3 each <br /> having substantial areas placed in buffer. The City requires a Conservation and Flowage <br /> Easement over each of the wetlands. In the case of all wetlands on this site, the required <br /> structure setback will be 10 feet landward of the edge of the wetland buffers, or 35' from the <br /> edge of the wetland itself, whichever is greater. <br /> Woodland Impacts & Conservation Design <br /> The developer submitted a Conservation Design Report and Master Plan which was reviewed <br /> with the original preliminary plat approval. In general, the development will maintain the rural <br /> character consistent with the surrounding neighborhood, Applicant has arranged the site to <br /> preserve the noted significant tree stands to the extent possible. To this end, the road corridor <br /> outlot extension and shared driveway construction just north of the Kintyre cul-de-sac has been <br /> configured to minimize impacts to the introduced conifers near the south end of the site. <br /> Wetlands and drainage patterns will be maintained, and the views into the site will not be <br /> significantly disrupted. A vegetation management plan spells out a variety of actions to be taken <br /> with regard to wetland buffer areas, buckthorn, and reed canary grass. The suggested Master <br /> Plan management guidelines will be incorporated in to the development agreement and <br /> covenants to assure adherence. <br />