My WebLink
|
Help
|
About
|
Sign Out
Home
Browse
Search
meeting notes re property
Orono
>
Property Files
>
Street Address
>
E
>
Edgewood Hills Road
>
1050 Edgewood Hills Road - 02-117-23-13-0003
>
Correspondence
>
meeting notes re property
Metadata
Thumbnails
Annotations
Entry Properties
Last modified
8/22/2023 4:06:24 PM
Creation date
8/23/2016 11:35:44 AM
Metadata
Fields
Template:
x Address Old
House Number
1050
Street Name
Edgewood Hills
Street Type
Road
Address
1050 Edgewood Hills Rd
Document Type
Correspondence
PIN
0211723130003
Supplemental fields
ProcessedPID
Updated
There are no annotations on this page.
Document management portal powered by Laserfiche WebLink 9 © 1998-2015
Laserfiche.
All rights reserved.
/
13
PDF
Print
Pages to print
Enter page numbers and/or page ranges separated by commas. For example, 1,3,5-12.
After downloading, print the document using a PDF reader (e.g. Adobe Reader).
View images
View plain text
■ From this lower floor elevation, you measure the building height. <br /> ■ Then subtract the difference between the lowest elevation and the highest or 10', whichever is <br /> less <br /> ■ This must be equal to or less than 30' <br /> There is also a subtraction based on the roof type, see definition of Building Height. <br /> In the existing house for example: (again,you would add a subtraction for type of roo� <br /> ■ Lowest grade elevation (rear garage)—989.0' <br /> ■ Highest elevation (front door)—1006.6' <br /> ■ 1006.6—989.0= 17.6' so we subtract 10' (the lesser value) <br /> ■ The existing height is roughly 1018.6' <br /> ■ (1018.6—989.0)—10= 19.6' so it is less than 30' and compliant. <br /> - This calculation is hard to determine without a schematic design, so we will reevaluate as we get further into <br /> the design. <br /> - Melanie and our team will meet again when we have a schematic scheme to discuss the building height further <br /> and to confirm that we're in compliance. <br /> Demolition <br /> - If we are planning on building in the existing non-conforming footprint in the front setback,the City requires <br /> further as-built documentation of the non-conforming spaces.This will be used to confirm compliance of the <br /> new build within the existing envelope. <br /> - Aside from the non-conforming space,the documentation we have is sufficient to demolish the house. <br /> - Need erosion control permit from Minnehaha Watershed District <br /> - Sewer disconnect permit required <br /> Miscellaneous <br /> - Currently,the variance process takes 6-8 weeks. It goes through the planning department and then the city <br /> council. Melanie will forward a 2015 schedule. Attached. <br /> - Building permit process is currently around 6 weeks. <br /> - We can move the curb cut if necessary. Generally,the City wants them kept to 20' wide plus the curb radius. <br /> - We are restricted to 15% "structural coverage" of the site.This includes the house, decks, large overhangs, etc, <br /> but excludes pools and patios. On this lot, it would be about 7500 sf. <br /> - Retaining walls are permitted in the setbacks. Walls over 4' in height need to be engineered and respect the <br /> "structure" setback from the property line. Melanie will provide the specifics of this setback. see above <br /> - No restrictions on tree removal or permit required <br /> - No impervious surface or FAR requirement. Only structure maximum of 15%. <br /> Thank you again Melanie and please let me know as soon as you are able if I have everything correct. <br /> Ted Martin AIA LEED AP <br /> 8 <br />
The URL can be used to link to this page
Your browser does not support the video tag.