§ 78-1540 ORONO CITY CODE •
<br /> Sec. 78-1540. Surfacing of loading berths. that half or more of the total number of
<br /> All loadi.ng berths and accessways shall be berths required shall be 50 feet in length.
<br /> improved with a durable material. (4) For other uses, there shall be provided
<br /> •(Code 1984, § 10.61(15)) adequate off-street loading space in con-
<br /> � nection with all structures which require .
<br /> Sec. 78-1541. Storage prohihited. receipt or distribution of materials by.
<br /> vehicles.
<br /> Any area allocated as a required loadi.ng berth (Code 1984, § 10.61(17)) . _ _ .
<br /> or access drive, so as to comply with the terms of '
<br /> this division, shall not be used for the storage of Secs. 78-1543-78-1565. Reserved.
<br /> � goods or inoperable vehicles nor be included as a
<br /> part of the area necessary to meet the off-street DIVISION 6. PERFORMANCE STANDARDS* � �
<br /> parking area.
<br /> (Code 1984, § 10.61(16)) Sec. 78-1566. Standards for all districts.
<br /> Sec. 78-1542. Required loading berths. The guiding of rural and suburban develop-
<br /> ment so as to develop a compatible relationship of
<br /> Where the pri.ncipal use of the structure served uses to achieve the purposes and guiding princi-
<br /> is as listed, the minim� number of loading ples established by this chapter depends upon
<br /> berths shall be as shown: certain standards being maintai.ned.Uses permit-
<br /> (1) Auditoriums,convention hall,public build- ted in the various districts;conditional and acces-
<br /> ing, hospital, school, hotel, sports arena, sory uses; and any use authorized by special
<br /> . at least one loading berth 25 feet in length Permit, variance, the application of any credit,
<br /> for each building having 1,000 to 10,000 formula or special planning procedure, such as �
<br /> square feet of floor area. For buildings �'�s or PIDs or other provisions of this chapter,
<br /> . having 10,000 to 100,000 square feet of shall conform to the standards of this division.
<br /> � floor area,one additional loading berth 50 These standards shall apply in all districts.
<br /> feet in length. (Cocle 1.984, § 10.60(1))
<br /> (2) Retail sales and service stores, offices, at Sec. 78-1567. Density. .
<br /> � least one loadi.ng berth 25 feet in length permitted uses or application of the various
<br /> for each building having 6,000 square feet provisions of this chapter or other laws,including
<br /> of floor area or more, plus one additional provisions relating to conditional and accessory
<br /> loading berth 50 feet in length for biuld- use, uses authorized by special permit, variance,
<br /> ings over 25,000 square feet up to 100,000 the application of any credit, formula, or special
<br /> square feet. �
<br /> planning procedure, whether singly or in combi-
<br /> (3) Manufacturing,fabrication,processing and nation, shall not result in a density greater than
<br /> warehousing, at least one loading berth four dwelling units per acre of dry buildable land
<br /> 25 feet in length for each building having or air space used for construction in any zoning
<br /> 3,000 square feet or fraction thereof, plus district.
<br /> one loading berth 50 feet in length for (Code 1984, § 10.60(2))
<br /> each 25,000 square feet of floor area up to
<br /> 100,000 square feet,plus one loading berth Sec. 78-1568. Noise.
<br /> for each 50,000 square feet of floor area p�y use established shall be so operated that
<br /> over the first 100,000 square feet of floor
<br /> area. The operator of the business shall no noise resulting from that use is perceptible
<br /> have the option to declaxe the length of beyond the boundaries of the plat line of the site
<br /> the berths required for buildings above �Cross references—Businesses,ch.26;environment,ch.
<br /> 100,000 square feet of floor area, except 58.
<br /> Supp.No.2 CD78:226
<br />
|