t � <br /> , f <br /> � File 08-3777 <br /> - � September 15, 2008 � <br /> Page 2 of 4 <br /> Background <br /> ' � This house was constructed in 1947 on two lots in a very old subdivision. The immediate <br /> past owner replaced the roof structure of the house but did no work on the deta.ched <br /> garage: � . • � . . . . . <br /> �� LOT ANALYSIS WORSHEET � � <br /> � � � Lot Area/Width• � <br /> Re uired Actual <br /> �� Lot Area 2 acres 0.288 acre <br /> � Lot Width 200 feet 100 feet • <br /> Principal Structure Setbacks: � � <br /> Re uired* Ezistin Pro osed <br /> Front 50' 62' No chan e .. <br /> Rear. _ . 50' . 37, . 23, <br /> � South Side 50' 17.66' 153' <br /> North Side 30' 41' No chan e <br /> . *The existing house cannot be expanded without variances. Although the front setback is 12 feet more <br /> than the minimum and#he north setback about 10 feet more than the minimum,when a structure with a � <br /> non-conforming setback is expanded the code requires the opposite setback to be increased by the amount <br /> of the setback deficiency. : <br /> Accessorv Structure Setbacks:� - <br /> , Re uired Existin Gara e Pro osed <br /> Front Setback of house 15'more than house 6' more than house <br /> setback setback <br /> Rear 10' 21' 33.4' <br /> . North Side 10' 4.5' S.1' <br /> Principal 10' 123' 123' <br /> Structure <br /> Structural Covera�e: <br /> Allowed Existin Proposed <br /> 1,823 s.f. 15% 1,597 s.£ 12.75% 1,771s.f. 14.08% <br />