Laserfiche WebLink
Sensible Heat Gain Subtotal from Page 1 �a'��/� O <br /> SQUARE DESIGN TEMPERATURE DIFFERENCE BTUH <br /> CEILING FEET �0 15 20 25 � �` HEAT GAIN <br /> HEAT TRANSFER MULTIPLIER <br /> No Insulation 14.9 17.0 19.2 21.4 22.5 23.6 <br /> R-11, 3" Insulation 2.8 3.2 3.7 4.1 4.3 4.5 <br /> R-19, 6" Insulation 1.8 2.1 2.3 2.6 2.8 2.9 <br /> R-30, 10" Insulation 1.1 1.3 1.5 1.6 1.7 1.8 <br /> R-38, 12" Insulation 0.9 1.0 1.1 1.3 1.3 1.4 <br /> FLOOR OVER SQUARE DESIGN TEMPERATURE DIFFERENCE BTUH <br /> UNCONDITIONED SPACE FEET �� HEAT TRANSFER ULTIPLI R � HEAT GAIN <br /> No Insulation 1.9 3.9 5.8 7.7 8.7 9.6 <br /> CARPET FLOOR-NO INSULATION 1.3 2.5 3.8 5.1 5.7 6.3 <br /> R-11, 3" INSULATION 0.4 0.8 1.3 1.7 1.9 2.1 <br /> R-19, 6" INSULATION 0.3 0.5 0.8 1.1 1.2 1.3 <br /> R-30, 10" INSULATION 0.2 0.4 0.6 0.7 0.8 0.9 <br /> /Z,�.�_ FLOOR Sn Ff. x�CEILING HEIGHT -/���CUBIC FT <br /> INFILTRATION/ <br /> VENTILATION 0.40 x CUBIC FT - 60 = �CFM <br /> MECHANICAL VENTILATION CFM = FRESH AIR INTAKE <br /> DESIGN TEMPERATURE DIFFERENCE BTUH <br /> CFM 10 15 20 25 � �` HEAT GAIN <br /> HEAT TRANSFER MULTIPLIER <br /> INFILTRATION / � 11.0 16.5 22.0 27.0 32.0 38.0 <br /> MECHANICAL VENTILATION /p 11.0 16.5 22.0 27.0 32.0 38.0 .,�c '� <br /> INTERNAL HEAT GAi BTUH HEAT GAIN <br /> Number of People x 300 3 <br /> Kitchen Allowance 1,200 <br /> SENSIBLE HEAT GAIN SUBTOTAL <br /> DUCT GAIN BTUH HEAT GAIN <br /> R-4, t" Fiexible Blanket Insulation: ADD 15% (.15) <br /> R-7, 2" Flexible Blanket Insulation: ADD 10% (.10) <br /> TOTAL SENSIBLE HEAT GAIN 3.2 9 <br /> LATENT LOAD CALCULATIONS <br /> Conditions Outdoor Wet Bulb Indoor Wet Bulb Grains <br /> Wet 80 62.5 50 <br /> Medium 75 62.5 35 <br /> Medium Dry 70 62.5 20 <br /> Dry 65 62.5 0 <br /> Based on 75°F Indoor Dry Bulb at 50% RH. <br /> LATENT LOAD-INFILTRATION <br /> 0.68 x � Grains x Infiltration CFM �7� �� <br /> LATENT LOAD-VENTILATION <br /> 0.68 x Grains x Ventilation CFM 3 4 <br /> LATENT LOAD-PEOPLE /� <br /> Number of People�x 230 �(/ <br /> TOTAL LATENT HEAT GAIN /� "^' <br /> TOTAL SENSIBLE AND LATENT HEAT GAIN �Z,%D <br /> NOTE: All Heat Transfer Multipliers from ACCA Manual "J" Sixth Edition and for a medium outdoor daily temperature range. <br /> CL-841-U 002345 Litho U.S.A. <br />