Laserfiche WebLink
/j O� <br /> � \ <br /> //O O 11. <br /> �. : ;:;;�,.- ` ,�p;� CITY of ORONO <br /> ' � ' !4� Municipal Offices <br /> ,�,� , ::� , ;,� Gti <br /> � ' ',�`�'' Street Address: MailinY Address: <br /> �9�C�ggOg'/ 2750 Kelley Parkway P.O. Box 66 <br /> = Orono, MN 55356 Crystai Bay, MN 55323-0066 <br /> �I^ <br /> Owner: � IY \ Address: 565 Ferndale Rd. N. <br /> Permit #'s: nona Dates: Contractors: un]cnown <br /> (�'his is [X1 an existing system O new construction) . <br /> ✓ � <br /> SYSTEM COMPLIANCE (1-3) : 3 <br /> 1 Code System: Meets or exceeds current City standards in all respects relating to design, <br /> construction, and location. Appears to be operating properly. <br /> 2 Compliant System: Does not meet all current City standards for new construction, but in <br /> most respects appears to be designed, located, and constructed in accordance with previous <br /> codes and is functioning properly. <br /> 3 Non-Compliant System: System may or may not meet current City standards for design, <br /> construction, or location, but is failing to properly treat and dispose of the current <br /> input; and any system with less than three feet of vertical separation between the bottom <br /> of the drainfield and the saturated soil level. <br /> (The saturated soil lavel is [x] or is not [ ] identified undar this septic system. If the <br /> saturated soil level is not identifiad, this classification is subject to revision.) <br /> TANK CONDITION (5-9) : 9 <br /> 5 Pumpcut not needed at this time. <br /> 6 Solids accumulation in tanks indicates they should be pumped out this year. <br /> 7 System is discharging to the surface. Tanks must be pumped out within 48 hours. <br /> 8 Inspection risers missing-tanks could not be inspected. If tanks have not been pumped out <br /> within three years, they should be pumped out and risers installed now. <br /> � Inspection pipe is located over tank baffle-can not measure solids accumulation. If tanks <br /> have not been pumped out within three years, they should be pumped out now. <br /> 10 One or more tanks are cesspools, which means the septic system is non-compliant. <br /> (The tanks are [ ] or are not [ ] water tiqht or the condition is �] unknown. If the tanks <br /> are not confirmed to be watartiQht, this classification is subject to revision.) <br /> AINFIELD CONDITION (11-14) : 11 <br /> 1 Drainfield is dry, no surfacing evident. <br /> 2 Some evidence of surfacing, not critical yet. Repair is not required at this time. <br /> 13 Drainfield is saturated and visibly discharging untreated effluent to the surface. <br /> Contact the City Inspector immediately. Repair must be completed within 90 days. <br /> 14 Drainfield extent and condition unknown. <br /> POTENTIAL FOR SYSTEM FAILURE: (system age and condition, soils, etc. ) : medium <br /> COMNIENTS: The septic system is non-compliant, but does not appear to pose an imminent threat to <br /> public health or safety (surface discharge or backup into the dwelling) . The system must be <br /> repaired or replaced by 12/31/2002 or within ninety days of posing an imminent threat to public <br /> health or safety, whichever comes first. <br /> ��q� <br /> Da e of Inspection ept'c System Inspector <br /> Note: In the event that this inspection report is used to satisfy the requirements for a <br /> transfer of property, this report does not guarantee that an existing system will continue to <br /> function properly, but indicates the operation of the system under current conditions. <br /> Telephone (612) 473-7357 • FAX 473-0510 <br />