My WebLink
|
Help
|
About
|
Sign Out
Home
Browse
Search
01-22-2008 Planning Commission Packet
Orono
>
Planning Commission
>
2008
>
01-22-2008 Planning Commission Packet
Metadata
Thumbnails
Annotations
Entry Properties
Last modified
7/27/2012 8:04:26 AM
Creation date
7/27/2012 8:04:18 AM
Metadata
There are no annotations on this page.
Document management portal powered by Laserfiche WebLink 9 © 1998-2015
Laserfiche.
All rights reserved.
/
160
PDF
Print
Pages to print
Enter page numbers and/or page ranges separated by commas. For example, 1,3,5-12.
After downloading, print the document using a PDF reader (e.g. Adobe Reader).
Show annotations
View images
View plain text
I } 1 ' <br /> � <br /> H �I� � BUILDING PLANNING <br /> SECTIO R302 installed or a whole-house mechanical ventilation <br /> �.. EXTERIOR WALL LOCATION system is installed capable of supplying outdoor ven- <br /> R302.1 Exterior walls. Construction, projections, openings tilation air of 15 cubic feet per minute(cfm)(78 L/s) <br /> � and penetrations of exterior walls of dwellings and accessory per occupant computed on the basis of two occupants <br /> buildings shall comply with Table R302.1. These provisions for the first bedroom and one occupant for each addi- <br /> shall not apply to walls,projections,openings or penetrations tional bedroom. <br /> in walls that are perpendicular to the line used to determine the 2. The glazed azeas need not be installed in rooms where <br /> fire separation distance. Projections beyorid the exterior wall Exception 1 above is satisfied and artificial light is pro- <br /> shall not extend more than 12 inches(305 mm)into the areas vided capable of producing an average illumination of <br /> where openings aze prohibited. 6 footcandles (65 lux) over the area of the room at a <br /> Exceptions• . height of 30 inches(762 mm) above the floor level. <br /> 1. Detached tool sheds and storage sheds, playhouses 3. Use of sunroom additions and patio covers,as defined in <br /> and similar structures exempted from permits are not Section R202,shall be pemutted for natural ventilation <br /> required to provide wall protection based on location if in excess of 40 percent of the exterior sunroom walls <br /> on the lot.Projections beyond the exterior wall shall az'e open,or are enclosed only by insect screening. <br /> not extend over the lot line. R303.2 Adjoining rooms. For the purpose of deternuning <br /> ' 2. Detached garages accessory to a dwelling located light and ventilation requirements, any room shall be consid- <br /> � within 2 feet(610 mm)of a lot line are permitted to ered as a portion of an adjoining room when at least one-half of <br /> � have roof eave projections not exceeding 4 inches �e area of the common wall is open and unobstructed and pro- <br /> ' �1�2 mm� � vides an,opening of not less than one-tenth of the floor area of <br /> ' 3. Foundation vents installed in compliance with this �e interior room but not less than 25 square feet(23 m2). <br /> code are permitted. Exception: Openings required for light and/or ventilation <br /> shall be permitted to open into a thermally isolated sunroom <br /> y addition or patio cover,provided that there is an openable <br /> SECTION R303 area between the adjoining room and the sunroom addition <br /> LIGHT,VENTILATtON AND HEATING � or pario cover of not less than one-tenth of the floor area of <br /> R303.1 Habitable rooms. All habitable rooms shall have an �e interior room but not less than 20 square feet(2 mz).The <br /> ' aggregate glazing area of not less than 8 percent of the floor �nimum openable area to the outdoors shall be based upon <br /> area of such rooms.Natural ventilation shall be through win- �e total floor azea being ven6lated. <br /> , dows,doors,louvers or other approved openings to the outdoor R303.3 Bathrooms. Bathrooms, water closet compartments <br /> � air.Such openings shall be provided with ready access or shall �d other similar rooms shall be provided with aggregate glaz- <br /> otherwise be readily controllable by the building occupants. ing area in windows of not less than 3 square feet(0.3 mz), <br /> � � The minimum openable area to the outdoors shall be 4 percent one-half of which must be openable. <br /> of the floor area being ventilated. <br /> , Exception:The glazed areas shall not be required where arti- <br /> , Exceptions: ficial light and a mechanical ventilation system are provided. <br /> 1. The glazed areas need not be openable where the The minimum ventilation rates shall be 50 cubic feet per min- <br /> opening is not required by Section R310 and an ute(24 L/s)for internuttent ventilation or 20 cubic feet per <br /> approved mechanical ventilation system capable of minute (10 L/s) for continuous ventilation. Ventilation air <br /> producing 0.35 air change per hour in the room is from the space shall be exhausted direcdy to the outside. <br /> I � TABLE R302.1 <br /> EXTERIOR WALLS <br /> MINIMUM MINIMUM FIRE <br /> EXTERIOR WALL ELEMENT FIRE-RESISTANCE RATING SEPARATION DISTANCE <br /> (Fire-resistance rated) 1 hour with ex osure from both sides 0 feet <br /> Walls <br /> � (Not fire-resistance rated) 0 hours 5 feet <br /> (Fire-resistance rated) 1 hour on the underside 2 feet <br /> Projections <br /> (Not fire-resistance rated) 0 hours 5 feet <br /> Not allowed N/A <3 feet <br /> Openings 25%Maximum of Wall Area 0 hours 3 feet <br /> Unlimited 0 hours 5 feet <br /> Com I with Section R3173 <5 feet <br /> Penetrations All <br /> None re uired 5 feet <br /> N/A=Not Applicable. <br /> 2006 INTERNATIONAL RESIDENTIAL'CODE� 4� <br />
The URL can be used to link to this page
Your browser does not support the video tag.