2006-P09944 - mechanical
Orono
>
Property Files
>
Street Address
>
F
>
Ferndale Road North
>
507 Ferndale Road North - 36-118-23-13-0007
>
Permits/Inspections
>
2006-P09944 - mechanical
Metadata
Thumbnails
Annotations
Entry Properties
Last modified
8/22/2023 5:01:18 PM
Creation date
8/16/2016 12:09:57 PM
Metadata
Fields
Template:
x Address Old
House Number
507
Street Name
Ferndale
Street Type
Road
Street Direction
North
Address
507 Ferndale Road North
Document Type
Permits/Inspections
PIN
3611823130007
Supplemental fields
ProcessedPID
Updated
There are no annotations on this page.
Document management portal powered by Laserfiche WebLink 9 © 1998-2015
Laserfiche.
All rights reserved.
/
16
PDF
Print
Pages to print
Enter page numbers and/or page ranges separated by commas. For example, 1,3,5-12.
After downloading, print the document using a PDF reader (e.g. Adobe Reader).
View images
View plain text
� Rhvac-Residential 8�Light Commerciai HVAC loads Elite Software Development,Inc. <br /> Minnesota Air Narr Construction <br /> Bloomington,MN 55438 Page 2� <br /> Project Report <br /> .� ___ <br /> General Project Information <br /> Project Title: Narr Construction <br /> Project Date: Wednesday, January 04, 2006 <br /> Project Comment: <br /> Client Name: Melrose Residence <br /> Client City: Orono, MN <br /> Company Name: Air Mechanical, Inc. <br /> Company Representative: Brian Ebert <br /> Company City: Ham Lake, MN <br /> Company Phone: (763)434-7747 <br /> Company Fax: (763)434-1699 <br /> Company Comment: <br /> Design Data __ _ '. <br /> -- -_ __ <br /> Reference City: Minneapolis, Minnesota <br /> Daily Temperature Range: Medium <br /> Latitude: 44 Degrees <br /> Elevation: 834 ft. ' <br /> Altitude Factor: 0.970 <br /> Elevation Sensible Adj. Factor: 1.000 <br /> Elevation Total Adj. Factor: 1.000 <br /> Elevation Heating Adj. Factor: 1.000 <br /> Elevation Heating Adj. Factor: 1.000 <br /> Outdoor Outdoor Indoor Indoor Grains ' <br /> Dry Bulb Wet Bulb Rel.Hum Drv Bulb Difference <br /> Winter: -20 0 30 72 34 <br /> Summer: 92 73 50 74 31 I <br /> Check Figures � <br /> _ __ __ _ __ -- ; <br /> Total Building Supply CFM: 1,822 CFM Per Square ft.: 0278 <br /> Square ft. of Room Area: 6,544 Square ft. Per Ton: 1,517 <br /> Volume (ft')of Cond. Space: 68,712 Air Turnover Rate (per hour): 1.6 <br /> Building Loads _� <br /> __ _--- _._— ---. _ i <br /> _ _ __ _ _ <br /> Total Heating Required With Outside Air: 113,600 Btuh 113.600 MBH ' <br /> Total Sensible Gain: 39,851 Btuh 81 % <br /> Total Latent Gain: 9,475 Btuh 19 % , <br /> Total Cooling Required With Outside Air. 49,326 Btuh 4.11 Tons (Based On Sensible+ Latent) I <br /> 4.31 Tons (Based On 77% Sensible Capacity) <br /> Notes � �� ����I <br /> _ ___ — — __. _ _ __ - <br /> Calculations are based on 8th edition of ACCA Manual J. <br /> All computed results are estimates as building use and weather may vary. <br /> Be sure to select a unit that meets both sensible and latent loads. <br /> I <br /> C:\Program Files\Elite\Rhvacw\Projects\Air Mech.,Narr C..,Rambler.rhv Wednesday, January 04, 2006, 1:51 PM <br />