My WebLink
|
Help
|
About
|
Sign Out
Home
Browse
Search
2006-P09944 - mechanical
Orono
>
Property Files
>
Street Address
>
F
>
Ferndale Road North
>
507 Ferndale Road North - 36-118-23-13-0007
>
Permits/Inspections
>
2006-P09944 - mechanical
Metadata
Thumbnails
Annotations
Entry Properties
Last modified
8/22/2023 5:01:18 PM
Creation date
8/16/2016 12:09:57 PM
Metadata
Fields
Template:
x Address Old
House Number
507
Street Name
Ferndale
Street Type
Road
Street Direction
North
Address
507 Ferndale Road North
Document Type
Permits/Inspections
PIN
3611823130007
Supplemental fields
ProcessedPID
Updated
There are no annotations on this page.
Document management portal powered by Laserfiche WebLink 9 © 1998-2015
Laserfiche.
All rights reserved.
/
16
PDF
Print
Pages to print
Enter page numbers and/or page ranges separated by commas. For example, 1,3,5-12.
After downloading, print the document using a PDF reader (e.g. Adobe Reader).
View images
View plain text
� . Rhvac-Residential 8�Light Commercial HVAC Loads � Elite Software Development,Inc. <br /> Minnesota Air Narr Construction'. <br /> Bloomington,MN 55438 Page 7, <br /> Detailed Room Loads - Room 1 - Main Level (Average Load Procedure) _ <br /> General _ _ _ _ _ _ _ _ ', <br /> _ _ � <br /> Calculation Mode: Htg. &clg. Occurrences: 1 <br /> Room Length: 3,272.0 ft. System Number: 1 <br /> Room Width: 1.0 ft. Zone Number: 1 <br /> Area: 3,272.0 sq.ft. SupplyAir: 1,327 CFM <br /> Ceiling Height: 11.0 ft. Supply Air Changes: 2.2 AC/hr <br /> Volume: 35,992.0 cu.ft. Required Vent.: 0 CFM <br /> Number of Registers: 16 Actual Winter Vent.: 170 CFM ' <br /> Runout Air: 83 CFM Percent of Supply.: 13 % <br /> Runout Duct Size: 6 in. Actual Summer Vent.: 109 CFM <br /> Runout Air Velocity: 422 ft./min. Percent of Supply: 8 % <br /> Design Loss: 0.100 in.wg./100 ft. Actual Winter infil.: 125 CFM <br /> Actual Loss: 0.112 in.wg./100 ft. Actual Sumrrier Infil.: 125 CFM <br /> Item Area -U- Htg Sen Cig Lat Sen <br /> Description Quantity Value _ HTM Loss HTM Gain Gain ; <br /> N -Wall-12E-Osw 99 X 11 750 0.068 6.3 4,692 1.4 0 1,040 <br /> S-Wall-12E-Osw 99 X 11 982 0.068 6.3 6,143 1.4 0 1,362 <br /> E-Wall-12E-Osw 56 X 11 594 0.068 6.3 3,716 1.4 0 824 <br /> W-Wall-12E-Osw 56 X 11 538 0.068 6.3 3,366 1.4 0 746 <br /> W-Door-11 N 6 X 7 42 0.350 32.2 1,352 10.2 0 426 <br /> N -Gls-3A-a-o shgc-0.37 100%S 339 0.370 34.0 11,540 13.7 0 4,634 ; <br /> S-Gis-3A-a-o shgc-0.37 0%S 107 0.370 34.0 3,642 23.5 0 2,515 , <br /> E-Gls-3A-a-o shgc-0.37 0%S 22 0.370 34.0 749 41.2 0 907 <br /> W-Gls-3A-a-o shgc-0.37 0°/oS 36 0.370 34.0 1,225 41.3 0 1,485 � <br /> UP-Ceil-16A-38 4250 X 1 4250 0.026 2.4 10,166 1.9 0 8,067 � <br /> Subtotals for Structure: 46,591 0 22,006 <br /> Infil.: Win.: 124.9, Sum.: 124.9 3,410 3.596 12,263 0.704 2,546 2,399 <br /> People: 230 lat/per, 230 sen/per: 4 920 920 <br /> Equipment: 1,000 3,000 <br /> Room Totals: 58,854 4,466 28,325 <br /> I <br /> � <br /> C:\Program Files\Elite\Rhvacw\Projects\Air Mech.,Narr C..,Rambler.rhv Wednesday, January 04, 2006, 1:51 PM <br />
The URL can be used to link to this page
Your browser does not support the video tag.