2008-00025 - new septic
Orono
>
Property Files
>
Street Address
>
F
>
Ferndale Road North
>
475 Ferndale Road North - 36-118-23-14-0012/0017
>
Septic
>
2008-00025 - new septic
Metadata
Thumbnails
Annotations
Entry Properties
Last modified
8/22/2023 5:02:02 PM
Creation date
8/15/2016 1:18:13 PM
Metadata
Fields
Template:
x Address Old
House Number
475
Street Name
Ferndale
Street Type
Road
Street Direction
North
Address
475 Ferndale Road North
Document Type
Septic
PIN
3611823140012
Supplemental fields
ProcessedPID
Updated
There are no annotations on this page.
Document management portal powered by Laserfiche WebLink 9 © 1998-2015
Laserfiche.
All rights reserved.
/
18
PDF
Print
Pages to print
Enter page numbers and/or page ranges separated by commas. For example, 1,3,5-12.
After downloading, print the document using a PDF reader (e.g. Adobe Reader).
View images
View plain text
07/09/2e08 10:37 952-955-5071 BURNS EXCAVATING PAGE 12 <br /> PRESSURE DISTRIBUTION SYSTEM <br /> 1. Select number of perforated laterals � � <br /> 2. Select per�oration spacing 3.0 <br /> 3. Since perforations should not be placed closer than 1 �t to the edge of the rock layer, <br /> subtract 2 fieet from the rock layer length. <br /> 75 minus 2 feet = 73 feet <br /> 4. Determine the number of spaces between pertorations. Divide the length above <br /> by the pertoration spacing and round down fio the nearest whole number. <br /> 73.0 divided 3.0 equals 2A�.3 spaces rounded down = 24 <br /> 5, Number of perforations is equal ta 1 plus the number of perforated spaces in step 4. <br /> 24 spaces plus 1 = 25 pertorations per lateral <br /> 6_ Multiply the pertorations per lateral by the number of laterals <br /> to get total number of pertorations. <br /> 25 X 3 equals 75 total number of perForations <br /> 7. Determine the required flow rate by multiplying the number of <br /> pertorations by the required perforations discharge from the table below. <br /> 75 perforations X 0.56 hole discharge = 42 gpm <br /> MAXIMUM NUMBER OF QUARTER fNCH P�RFORATIONS PER REQUIRED PERFORATION DISCHARGE <br /> LATERAL TO GUARANTEE<10°k OISCHARGE VARIATION IN GALLONS PER MINUTE GPM <br /> PERF SPACING IN FEET 1.25 fN PIPE 1.5 IN PIPE 2,0 IN PIPE OISC.HFAD 7/32 IN PERF 1/�}IN PERF <br /> 2.5 14 16 28 1.0 a D.56 0.74 <br /> 3,0 13 17 26 2.0 b O.B 1.04 <br /> 3.3 12 16 25 a. USEO FOR SINGLE FAMILY HOMES <br /> 4.0 11 15 23 b_ USED FOR ALL OTHER APPIICATION <br /> �,0 10 14 22 <br /> 8. If HEADER P(PE is connected to the END of the laterals, select minimum required lateral <br /> diameter from table above with perForation spacing and number of perForations per <br /> lateral. Select minimum diameter for the perforated lateral. <br /> You have selected ft spacing and perfs per lateral <br /> 2_00 inch minimum diameter laterals <br /> 9. If HEADER PIPE is connected to th� C�NTER ofi the laterals, perts per lateral are 1/2, <br /> select minimum required lateral diameter from table above with pertoration spacing and <br /> number af pertorations per lateral. Select minimum diameter for the pertorated lateral, <br /> You have selected 3.0 ft spacing and 25.0 perts per lateral <br /> 2.00 inch minimum diameter late►'al <br /> PAG� 7 OF 12 <br />