Laserfiche WebLink
� ,r T � � � � � � � � � � � � � � � Project Specifications: Labeling: Notes: Inverter Specifications: Special Wiring Legend: <br /> , � Inverters:690.5(C)States-A warning Note#l:lnverters contain integrated Brand/Model-SolarEdge SE3800A-US <br /> pp y q Continuous Output Current-16A """"'Groundin Electrode Conductor GEC <br /> label shall a ear on the utilit AC/DC disconnects as re uired in 9 ( ) <br /> � ' Certification: All inverters are ULU41 or equivalent. interactive inverter or one shall be Artide 690 in the NE�.PV Source Naminal AC POW2►Output-3,800W ^�' Equipment Grounding Conducto�(EGQ <br /> installed to indicate:"WARNING- Circuits according to 690.9(A)Exp. yyei hted CEC Effi<ienC 98% <br /> ' If inverter(s)types areTransformerless and the DC ELECTRIC SHOCK HAZARD IF GROUND (b)does not require overcurrent 9 y �/'t� WEEB or Equivalent EGC ConneCtlOn <br /> Area EPS Photovoltaic Source,output,and input circuts are FAULT IS INDICATED,NORMALLY protection. Max.input Voltage-500 vdc(voc) <br /> � 1 umgrounded.Black(-)and Red(+)shall be used for GROUNDED CONDUCTORS MAY BE Nominal DC input-350V ��Control CirCUit 120V <br /> ' � wiring. UNGROUNDED AND ENERGIZED. Note#2: Grounding electrode such Maximum DC Power(STC)-5,100W --Communication Circuit(Cat Se or 6e) <br /> � ' as Building Steel,ground rod,&etc. �(I5c-13A <br /> � Buildingsw/PV&UtilityServices:Building �Un-GroundedDCConductors <br /> ' If Applicable: shall be supplied with a permanent Note#3:Buildings Grounding ACVoltage Range-211-264V <br /> Q Local EPS , Production meter to be wired"LINE"to Utilit and AC Nominal Valta e-240V-1 PH <br /> Y plaque or directory indicating where the Electrode System. 9 <br /> '� "LOAD"to solar. service and photovoltaic systems AC FPequency Range-59.3-60.5 Hz <br /> ' disconnects are located if in a differant Note#4: Integrated AV DC Disconnect-optional <br /> � ' If Applicable: location. <br /> w Connection from"Production Meter"to"Bi-Direction- NoteiFS:Lockable AC disconnect to weight-51.2 Ibs. <br /> ' � Bi-Directional al Meter"by a dual lug system in meter similar or All otherlabels:All labels shall comply with be visable/accessible and located <br /> ,�,,., Meter ' equal to a Milbank K4977-INT. the corosponding label number on less than 10 feet from existing Main <br /> �� 120/240 V `Labeling Requirements"and there Service and Identified with a light + ,�,. !'`;,-'-, <br /> ' a--+ M., �2�OA If Xcel Energy: perspective numbering.5ome labels refleding label. e'VI�w�� �"� �r•`�''�`" <br /> Two above notes not applicable.Connection from come inte ral on s stem e ui ment and <br /> '� � O 9 y 4 p C pliance City of ��ano Equipment List: <br /> "Production Meter"to Bi-Directional meter will use must be verified,as not to double label <br /> junction box as shown in diagram.Production Meter equipment. / II1VQPt2C:(1)SolarEdge <br /> ' Socket to be installed will have bypass Lever. Da� ` SE5000A-US <br /> ' � Modules:(18) Heliene 280W <br /> ' �@VI @t <br /> ' Mono <br /> � ��� UtilityDisconnect: Square D <br /> � � <br /> � � � 120/240VAC/60A 1 PH 3R <br /> ' � Utility Meter:Milbank <br /> �`�� ���� � � � � � � � � Module Specifications: 120/240V 200A <br /> Brand/Model-SolarWorld SW 285 mono <br /> '�' ' Max.Power at STC(+5W/-OW)-285 W <br /> Efficiency at STC- 17% Energy Monitoring:n/a <br /> ' � ' 11altageatMax.Power-313vdc(Vmp) <br /> � Main OCPD furrent at max.Power-9.84A(I mp) <br /> ' Q 200A ' OpenCircuitVoltage-39.7vdc(Voc) Customer: <br /> �� Panel Board Junction ShortCircuitCurrent-9.84A(Isc) <br /> � � 1PH120/240 BoX : Max.VoltageUVIEC-600/1000vdc TommRobb <br /> LLJ ' 60A SeriesFuseRating-15A 570 Big Island <br /> n n W W Dimensions(LxWxD)-65.95"X39.4"X13" <br /> � �1 — — � ' Fused Wayzata MN 55391 <br /> � ^ � DisC. 612-799-3278 <br /> �N � � _ <br /> n n ' - See Note#5 <br /> 'w �� �� See Note#3 <br /> y ' O �C - + - + Project Information: <br /> ' � �� �� String of iS Heliene 280W <br /> � ' PV Production AC p� Totaling5.04kW p� 5.04kW Roof Mount <br /> 'O Meter Line � Optimizer _ _ _ _ _ _ _ _ Optimizer PV Solar System <br /> N ' Single Phase,3 <br /> � � M Q See Note#1 � <br /> , Wire � <br /> V � � � � � � 120-24�V �— � SolarEdge SESOOOA-US � � � <br /> 200A Load SeeNote�2 <br /> #PV-1 L-101 <br /> (1-Line Diagram) <br /> Installer: <br /> Able Energy Corp. <br /> Production meter to be 265 Mound View Rd. <br /> within 10ft of utility meter River Falls,WI 54022 <br /> (715)629-9335 <br /> � � <br /> �b �� <br /> . _} <br />