My WebLink
|
Help
|
About
|
Sign Out
Home
Browse
Search
2016-00745 - mechancial
Orono
>
Property Files
>
Street Address
>
B
>
Big Island
>
570 Big Island - PID: 22-117-23-31-0029
>
Permits/Inspections
>
2016-00745 - mechancial
Metadata
Thumbnails
Annotations
Entry Properties
Last modified
8/22/2023 4:11:46 PM
Creation date
8/10/2016 8:21:43 AM
Metadata
Fields
Template:
x Address Old
House Number
570
Street Name
Big Island
Address
570 Big Island
Document Type
Permits/Inspections
PIN
2211723310029
Supplemental fields
ProcessedPID
Updated
There are no annotations on this page.
Document management portal powered by Laserfiche WebLink 9 © 1998-2015
Laserfiche.
All rights reserved.
/
47
PDF
Print
Pages to print
Enter page numbers and/or page ranges separated by commas. For example, 1,3,5-12.
After downloading, print the document using a PDF reader (e.g. Adobe Reader).
View images
View plain text
Able Energy <br /> SNOW <br /> Ref ASCE 7-10 Chapter 7 <br /> Balanced/Unbalanced Case <br /> Ground snow load for this application P9 a `� � <br /> Section 7.3 applies,Pf=.7 Ce Ct I Pg <br /> Exposure factor Ce,per table 7.2 Ce= 1 <br /> Thermal factor Ct Ct= 1.2 <br /> Importance factor I pertable 7.4 �_ � <br /> Snow load(P�as per sec 7.3 pf= 42 psf <br /> .5 pf .5Pf= 21 psf <br /> Unobstructed/Slippery Surface? YES <br /> Cs from Figure 7.2 Cs= 1.00 <br /> 2Pf Cs/Ce 2Pf Cs/Ce= 84.0 psf <br /> Ps=CsPf 42.0 psf <br /> Flat Roof Systems <br /> USE CASE A <br /> PS 42 psf <br /> PS Balanced Selected I <br /> Applyin flat roof subcharge tor Ps<20psf Cs x pf 42.0 <=Value <br /> DO NOT USE CASE B for W<20 DOES NOT APPLY <br /> Case B,Unbalanced with W<20ft, roof rafterlgable system <br /> ----_..__ _. -___._. <br /> �X Pg 50 psf <br /> Appl in the Slope Reduction Factor Cs x pf 50.0 psf <br /> DO NOT USE CASE 62 DOES NOT APPLY Case B,Other Unbalanced for W>20ft <br /> 13ft <br /> 12.6 �sf hdb/SQRT(S) 16.8 psf <br /> .3Ps � <br /> �, � psf <br /> Ps max 58.8 psf <br /> Roof Rafter system? Yes <br /> eave to ridge W(ft)= 15.00 <br /> use Case A <br /> Hip or gable Roof? NO <br /> Rise(in) 23.28 DO NOT USE DOES NOT APPLY <br /> Run(in) 139.08 ASCE 7-10 Monoslope <br /> S= 5.974 <br /> e(degrees)= 9.5 f�s/Ce <br /> Unbalanced Load .Spf <br /> Test Cases <br /> e(degrees)= 70.0 <br /> 9 M��(degrees)= 5.17 Eaves Crown Eaves <br /> Unbalanced Analysis? Use case B Balanced Load • ��s��ffig�2 � <br /> b= 20.5 Pf <br /> SQRT(S)= 2.4 <br /> lu(ft)= 20 <br /> hd= 2.00 Eaves Crown Eaves <br /> hdb/SQRT(S)= 16.8 <br /> 8/3 x hd SQRT(S)= 13.0 <br /> 0.3Ps= 12.60 <br /> Sheet 10 <br />
The URL can be used to link to this page
Your browser does not support the video tag.