My WebLink
|
Help
|
About
|
Sign Out
Home
Browse
Search
Preliminary Septic Design
Orono
>
Property Files
>
Street Address
>
B
>
Bayside Trail
>
100 Bayside Trail - 06-117-23-22-0026
>
Septic
>
Preliminary Septic Design
Metadata
Thumbnails
Annotations
Entry Properties
Last modified
8/22/2023 5:25:07 PM
Creation date
8/9/2016 3:29:09 PM
Metadata
Fields
Template:
x Address Old
House Number
100
Street Name
Bayside
Street Type
Trail
Address
100 Bayside Tr
Document Type
Septic
PIN
0611723220026
Supplemental fields
ProcessedPID
Updated
There are no annotations on this page.
Document management portal powered by Laserfiche WebLink 9 © 1998-2015
Laserfiche.
All rights reserved.
/
14
PDF
Print
Pages to print
Enter page numbers and/or page ranges separated by commas. For example, 1,3,5-12.
After downloading, print the document using a PDF reader (e.g. Adobe Reader).
View images
View plain text
Installer Summary <br /> 2000 gatlon Septic tank �minimum) Tank options: none <br /> �u� �arger iann wi�n rnuiupie coniNi�anKs <br /> 1000 gallon Dose tank (minimum) at 25.00 gp� <br /> 29 GPM C� 17 ft. of head, Pump required <br /> � 5.3 inch swing on Demand float which translates to roughly 3.7 inches of ftoat tether length <br /> if time dosing is required --> 4.6 minutes ON time 8 �hours OFF time <br /> 17 inches from bottom of tank to "pump ON" ftoat, or 12 inches to "timer ON"ftoat <br /> 20 inches from bottom of tank to"Hi �evel Atarm" or 30 inches to "Hi tevel atarm" if time dosed <br /> 120 ft. of 2.0 inch supply line with end feed manifold connection <br /> ITip: "top feed" manifold to control drainback) <br /> 16 inch, or 1.3 ft. Sand Lift Mound <br /> 10.0 ft. wide by 38.0 ft. long Rock bed <br /> 3 taterals 2.00 inch diameter 36.0 ft. tong 3.0 ft. laterat spacing <br /> 1/4" inch perfs 3.0 ft. perforation spacing <br /> No Effluent filter fx alarm <br /> 3 clean out 8 valve box assemblies <br /> 20.0 ft.Total sand ABSORPTION width �minimum) <br /> 0.0 ft. upslope and sideslope �sand beyond rockbed, minimum) <br /> i 10.0 ft. Downslope �sard bevcnd rockbeti. �inim��,r-,,i <br /> Specific slope ratios give BERM widths (topsoil beyond rockbed) of: <br /> 4:t upslope ratio 10 ft. upslope berm <br /> 3:1 sideslope 12 ft. sideslope berms <br /> 3:1 downslope 20 ft. downslope berm <br /> 4" inspection pipe <br /> 18" cover on top <br /> U slo e berrn � �� \ Downslo e berm 2C' <br /> ,,. 12" cover on side5 <br /> '� ` i.6"loamy cap&6"tops�il) <br /> 1.3 Clean sar�d ,:f; ���`� <br /> ,..,`�_ <br /> i <br /> ,, , �,.. <br /> 1.7 ;� .� :; ,. - <br /> . .� Absor tion Width 20.0 <br /> Note: <br /> For 0 ta 1� slopes, Abso�ption Width is measured from the Bedequally in both direction5. <br /> For slopes 71%, Absarption Width is measured �iownhitl from the upslope edge of the Bed. <br /> Rock Bed: 13.0 yd3 or'1.4= 18 ton 6 inches under pipe <br /> Mound Sand: 110 ydJ o�"�•4= 155 ton calculation based on 3:1/4:1 stope from top of rockbe� <br /> Loamy Cap: 47 yd' or`1.4= 66 ton 6" deep <br /> Topsoil: 56 yd3 or"1.4= 7g ton 6"deep <br />