My WebLink
|
Help
|
About
|
Sign Out
Home
Browse
Search
2016-00796 - new construction
Orono
>
Property Files
>
Street Address
>
B
>
Bayside Trail
>
100 Bayside Trail - 06-117-23-22-0026
>
Permits/Inspections
>
2016-00796 - new construction
Metadata
Thumbnails
Annotations
Entry Properties
Last modified
8/22/2023 5:25:04 PM
Creation date
8/9/2016 3:25:26 PM
Metadata
Fields
Template:
x Address Old
House Number
100
Street Name
Bayside
Street Type
Trail
Address
100 Bayside Tr
Document Type
Permits/Inspections
PIN
0611723220026
Supplemental fields
ProcessedPID
Updated
There are no annotations on this page.
Document management portal powered by Laserfiche WebLink 9 © 1998-2015
Laserfiche.
All rights reserved.
/
82
PDF
Print
Pages to print
Enter page numbers and/or page ranges separated by commas. For example, 1,3,5-12.
After downloading, print the document using a PDF reader (e.g. Adobe Reader).
View images
View plain text
E Load Short Form Job: H062816NORD <br /> "�" Wi�l�f'1�SO� Date: Jun 28,2016 <br /> Entire Mou�e ��� By: MIKE RQWE <br /> Goodin Company �� �� RECEIVED <br /> �� <br /> 2700 2nd slreet north,h�inneapolis,h1N 55411 Phone:812-588-7811 Fax 6f2-588-8132 Email:mike.roweCgoodinco.Com Web:v�vw.goodincaldd� 1 1 2016 <br /> ° e s • <br /> Far: NORD, GALLAGHER HEATING <br /> ORONO, MN <br /> @ • • e • <br /> Htg Clg Infiltration <br /> Dutside db(°F) -15 88 Method Simplified <br /> Inside db (°�) 72 75 Construction quality Tight <br /> Design TD (°F) 87 13 Fireplaces 2(Average} <br /> Daily range - M <br /> Inside humidity(%) 5 50 <br /> Moisture difference(grJlb) 4 28 <br /> HEATING EQUIPMENT COOLING EQUIPMENT <br /> Make Make <br /> Trade 7rade <br /> Model Cond <br /> ANRI ref Coil <br /> AHRI ref <br /> Efficiency 90AFUE Efficiency Q SEER <br /> Heating input 0 Btuh Sensible cooling 0 Btuh <br /> Heating output 0 Btuh Latent coofing 0 Stuh <br /> Temperature rise 0 °F Total cooling 0 Btuh <br /> Actual air flow 1415 cfm Actual air flow 1415 cfm <br /> Air flow factor 0.016 cfmlBtuh Air flow factor 0.042 cfm/Btuh <br /> Static pressure 0 in H20 Sfatic pressure 0 in H2� <br /> Space thermostat Load sensible heat ratio 0.83 <br /> ROOM NAME Area Htg load Clg load Htg AVF Clg AVF <br /> (ft2) (8tuh) (Btuh} (cfm) (cfm} <br /> BASEMENT 1915 30689 13015 476 541 <br /> MAIN LEVEL 2134 6060fl 21037 940 874 <br /> Entire House 4049 91289 34052 1415 1415 <br /> Other equip loads Q 0 <br /> Equip. @ 0.93 RSM 31601 <br /> Latenf cooling 6773 <br /> TOTALS 4049 91289 38374 1415 1415 <br /> Catculations approved by ACCA to meet all requirements of Manual J 8th Ed. <br /> 2016-J un•28 11:35:13 <br /> � � wrightsoft� Rghl-Suite�J U�iversal 2013 13.0.15 RSU15012 pa9e } <br /> fK.C� Z:IWrightsoft NVRC1ProjecHMIKE RIH062816NORD.rup Cale=A1J8 Front Door faces: S � <br />
The URL can be used to link to this page
Your browser does not support the video tag.