<br /> 0.�.4� o
<br /> �,���i:���;�,-� CITY of ORONO
<br /> ,� ;'��`= , ��r -3 �
<br /> � �,;�I°`',.�i � Municipal Oflices
<br /> . '�+,'� ,��,,,�,#.;,�;`:��d�� G �
<br /> � .,, ,,�, .�� �� Street Address: Mailing Address:
<br /> 9kEggo4i" 2750 Kelley Parkway P.O. Boz 66
<br /> Orono, MN 55356 Crystal Bay, MN 55323�0066
<br /> To Current Owner: Address: ���� �``� U��"' 1--`���
<br /> City Ordinance 199 requires that each existing on-site sewage treatment system in Orono be inspected every two years.
<br /> The on-site sewage treatment system at the above address has been inspected and appears to fall into the categories checked below.
<br /> YSTEM CONFORMITY (1-3): ,�
<br /> 1 "CODE SYSTEM" An ISTS which meets all the location,design and construction standards of the current Orono Municipal Code.
<br /> 2 "COMPLIANT SYSTEM" An ISTS which does not meet all the location,design and construction standards of the current Orono Municipal
<br /> Code but does meet the three foot sepazation requirement or two foot requirement for systems installed 1996 or earlier,and which is not failing or
<br /> an imminent threat to public health or safety.
<br /> 3 "NON-COMPLIANT SYSTEM'� A prohibited ISTS;an ISTS located within a designated 100-yeaz flood plain,any ISTS which may
<br /> or may not meet all the location,design,or constniction standards of the current Orono Municipal Code and which is failing for any reason;and
<br /> any ISTS with less than three feet of unsaturated soil or sand beriveen the distribution device and the limiting soil characteristics.
<br /> TANK CONDITION(5-7): �
<br /> Tank inspection indicates:
<br /> �Pumpout not needed at this time.
<br /> Septic tanks must be pumped out this year (city code requires tanks to be pumped out once every 3 years.
<br /> Tank was last pumped ).
<br /> Make sure septic tanks are pumped throu�h manhole and not throu�h white inspection pipes. This allows for the
<br /> proper cleaning. Keep water softner and iron filter dischar�e out of septic svstem.
<br /> 7 Inspection risers missing-tanks could not be inspected. Inspection risers (4" dia. pipe)must be installed in each tank. If
<br /> tanks have not been pumped out within the last three years,they should be pumped out now.
<br /> DRAINFIELD CONDITION 8-10 : �
<br /> 8 Drainfield is dry,no surfacing evident.
<br /> 9 Some evidence of surfacing, not critical yet.
<br /> 10 Drainfield is saturated and visibly discharging untreated effluent to the surface. Contact the City Inspector
<br /> immediately.Repairs must be completed within 90 days.
<br /> COMMENTS: r'� �^� d ��ICS �I`_ ���^� St P�',Z- �'`'��K-S S�`^^,',z�
<br /> � �`t
<br /> � ,-� - �� �.�: ��..
<br /> Date of Inspection Matt Bolterman - Septic System Inspector
<br /> Note: In the event thatthis inspection report is used to satisfy the requirements for a mortgage or other transfer of property,be advised that this report does not guarantee
<br /> or certify that an existing system wili continue to function properly,but is merely an opinion ofthe adequacy ofthe system under current conditions based on the available
<br /> information.
<br /> Telephone(952) 249-4600 • Fax(952)249-4616
<br /> ..,�z.�,., ,,..,,,,�,.,.,„�
<br />
|