Laserfiche WebLink
/ � �`V <br /> 0� = - ° I <br /> � �. CITY of OlaONO <br /> i � ��r� _� <br /> �� i , •�, � <br /> „� ' R �, �ti MunicipalOffices <br /> , <br /> sf , <br /> �� � � ��`�,�ti rr ��1 V <br /> ����� �:, , "�'rg� Street Address: Mailing Address: <br /> �EBHp 2150 Kelley Parkway P.O. Box 66 <br /> �__ Orono, MN 55356 Crystai Bay, MN 55323-0066 <br /> Owner: !J � Address: 3051 Farview Ln. <br /> Permit #'s: 6217 Dates: 12/9/80 Contractors: Westonka Plbg. <br /> (This is [�] an existing system [ ] new construction) . <br /> J� <br /> SYSTEM COh;PLZANCE (1-3) : 1 <br /> 1 Code System: Meets or exceeds current City standards in all respects relating to design, <br /> construction, and location. Appears to be operating properly. <br /> 2 Compliant System: Does not meet all current City standards for new construction, but ir, <br /> most respects appears to be designed, located, and constructed in accordance with previous <br /> codes and is functioning properly. <br /> 3 Non-Compliant System: System may or may not meet current City standards for design, <br /> construction, or location, but is failing to properly treat and dispose of the current <br /> input; and any system with less than three feet of vertical separation between the bottom of <br /> the drainfield and the saturated soil level. <br /> (The saturated soil level is ['�] or is not [ ] identified under this septic system. If the <br /> saturated soil level is not ide{itified, this classification is subject to revision.) <br /> TANK CONDITION (5-9) : 9 <br /> 5 Pumpout not needed at this time. <br /> 6 Solids accumulation in tanks indicates they should be pumped out this year. <br /> 7 System is discharging to the surface. Tanks must be pumped out within 48 hours. <br /> 8 Inspection risers missing-tanks could not be inspected. If tanks have not been pumped our <br /> within three years, they should be pumped out and risers installed now. <br /> �9 Inspection pipe is located 'over tank baffle-can not measure solids accumulation. If tanks <br /> have not been pumped out within three years, they should be pumped out now. <br /> 10 One or more tanks are cesspools, which means the septic system is non-compliant. <br /> (The tanks are [ ] or are not ( ] water tight or the condition is [ ] unknown. If the tanks <br /> are not confirmed to be watertight, this classification is subject to vision.) <br /> INFIELD CONDITION (11-14) : 11 <br /> 1 Drainfield is dry, no surfacing evident. <br /> Some evidence of surfacing, not critical yet. Repair is not required at this time. <br /> 13 Drainfield is saturated and visibly discharging untreated effluent to the surface. Contact <br /> the City Inspector immediately. Repair must be completed within 90 days. <br /> 14 Drainfield extent and condition unknown. <br /> POTENTIAL FOR SYSTEM FAIi.unc.: (syster:, aya and condition, soils, etc. i : high <br /> COMMENTS: In order to confirm that your septic system meets Minnesota standards, soil borings <br /> were performed to verify a 3 foot separation between the drainfield and the seasonal water table. <br /> The separation is 3 feet and the system is compliant. <br /> ����'q � ,d-_ <br /> Date of Inspection Se ic System nspector <br /> Note: In the event that this inspection report is used to satisfy. the requirements for a <br /> transfer of property, this report does not guarantee that an existing system will continue to <br /> function properly, but indicates the operation of the system under current conditions. <br /> Telephone(612)249-4600 • Fax(612)249-4616 <br />