Laserfiche WebLink
SEPTIC SYSTEM INVENTORY <br /> Address: 2800Farview Ln. PID: 04-1 17-23 34 0006 <br /> Building Typexesidence BRs Install'd for: 3 In Musa: Yes <br /> Permit#: 7915 Date of Permit: 5/13/85 Installer: Westonka Plbg. <br /> System Type: standard trench Performance: no Tank Filter: <br /> SYSTEM CONDITION <br /> Conformity: 3 Tank Condition: 5 DF condition: 8 Failure Pot: medium <br /> SEPTIC TANKS <br /> Material: precast concrete Capacity: 1000, 1000 <br /> Setback to Bldg: 30 Cesspool: no <br /> DRAINFIELD <br /> Length of Lines: 290 # Lines: 3 Trench Width: 3 <br /> Treatment Area: 870 Type of Filter: rock Soil Boring: yes <br /> Tile Size: 4 Under Tile: 12 Perc Rate: 23.5 <br /> Setback DF-Bldg: 40 DF Ht above Wt: 0.6 <br /> Soil Type: loam, clay loam Limitations: water table <br /> WELL DATA <br /> Setbacks - Well-Tanks: 50 Well-DF: 75 Report in File yes <br /> Pump Type: subm. Depth: 106 Diameter: 4 Method: drilled <br /> INSPECTION RECORD PUMPOUT RECORD <br /> DATE DESCRIPTION COMPLIANCE DATE GALLONS <br /> 5/20/85 installation 1 9/16/91 2000 <br /> 8/6/87 no surfacing 1 5/30/97 2000 <br /> 7/30/90 no surfacing 1 11/12/03 2000 <br /> 7/18/91 no surfacing-need risers, pump tanks 1 <br /> 10/28/94 no surfacing-pump tanks l <br /> 8/23/96 no surfacing 1 <br /> 6/1/99 non-compliant-repair by 12/31/2009 3 <br /> 7/10/O1 non-compliant,replace by 12/31/2010 3 <br /> 7/29/03 non-compliant,replace by 12/31/2010 non-compliant <br /> �J-0� � � �, <br /> , GI ( -� � � � <br /> � �- <br /> � � �Q �.�� <br />