04-16-2007 Planning Commission Packet
Orono
>
Planning Commission
>
2007
>
04-16-2007 Planning Commission Packet
Metadata
Thumbnails
Annotations
Entry Properties
Last modified
7/24/2012 4:23:19 PM
Creation date
7/24/2012 4:15:32 PM
Metadata
Jump to thumbnail
< previous set
next set >
There are no annotations on this page.
Document management portal powered by Laserfiche WebLink 9 © 1998-2015
Laserfiche.
All rights reserved.
/
540
PDF
Print
Pages to print
Enter page numbers and/or page ranges separated by commas. For example, 1,3,5-12.
After downloading, print the document using a PDF reader (e.g. Adobe Reader).
Show annotations
View images
View plain text
l3' . • <br /> °�---- <br /> 2335 Highway 36 W • <br /> St.Paul,MN 55113 <br /> Tel 651•636-4600 <br /> Fax 651-636-1311 <br /> www.bonestrao,com <br /> March 7, zoo� �Bonestroo <br /> Mr, Michael Gaffron <br /> Planning Director <br /> City of Orono <br /> Post Office Box 66 <br /> Crystal Bay, MN 55323 <br /> Re: 2001 Sugar Woods Drive <br /> File No. 000139-07000-1 <br /> Dear Michael: <br /> We have reviewed the grading and drainage plan for the property at 2001 Sugar Woods Drive, dated 2-14- <br /> 07,We have the following comments with regards to engineering matters: <br /> , • Storm drainage calculations should be provided to verify the proposed storm sewer has sufficient � <br /> capacity to handle the associated drainage area, This should include providing a drainage area � <br /> map containing all areas draining to this property, , <br /> • Drainage&utility easements should be provided over the proposed storm sewer. <br /> • The building elevation to the north of this projed is conservatively at 1009:0, This will require an <br /> emergency over flow elevation no higher than 1008,0 likely to be located in the proposed driveway <br /> area, This emergency over flow point should be clearly indicated on the grading plans. <br /> • Some of the proposed retaining walls are four feet in height. Prior to making any field changes <br /> that would increase the height of the proposed retaining walls, engineered design and details must <br /> be submitted for review and approval. <br /> • The garage floor drain may not be able to be connected to the sanitary sewer, The applicant <br /> should discuss available options with the city's building official. <br /> • Revise CBMH 3 Detail to reflect City Standard Detail Plates(See attached detail plates), <br /> If you have any questions, please call me at(651)604-4894, <br /> Yours very truly, <br /> BONESTR00 <br /> �--. <br /> � `r—.�� i . �-�� <br /> ---_ <br /> Darren Amundsen <br /> Cc; Tom Kellogg <br />
The URL can be used to link to this page
Your browser does not support the video tag.