Laserfiche WebLink
� <br /> - � � pCH��1 t N � <br /> BUILDING PLANNING <br /> f <br /> 1 <br /> t <br /> i <br /> ! <br /> i <br /> SECTIO R302 installed or a whole-house mechanical ventilation <br /> �.. EXTERIOR WALL LOCATION system is installed capable of supplying outdoor ven- <br /> R302.1 Exterior walls. Construction, projections, openings tiladon air of 15 cubic feet per minute(cfm)(78 L/s) <br /> and penetrations of exterior walls of dwellings and accessory per occupant computed on the basis of two occupants <br /> buildings shall comply with Table R302.1. These provisions for the first bedroom and one occupant for each addi- <br /> shall not apply to walls,projec6ons,openings or penetrations tional bedroom. <br /> in walls that are perpendicular to the line used to deternune the 2. The glazed azeas need not be installed in rooms wh�re <br /> fire separation distance. Projections beyorid the exterior wall Exception 1 above is satisfied and artificial light is pro- <br /> shall not extend more than 12 inches(305 mm)into the azeas vided capable of producing an average illuminatio�of <br /> where openings are prohibited. 6 footcandles (65 lux) over the area of the room t a <br /> Exceptions: height of 30 inches(762 mm)above the floor leve�. <br /> 1. Detached tool sheds and storage sheds, playhouses 3. Use of sunroom additions and patio covers,as defineG�in <br /> and similar structures exempted from permits are not Sec�ion R202,shall be pernutted for natural ventilation <br /> required to provide wall protection based on location if in excess of 40 percent of the exterior sunroom walls <br /> on the lot.Projections beyond the exterior wall shall are open,or are enclosed only by insect screening. ! <br /> not extend over the lot line. R303.2 Adjoining rooms. For the purpose of deternumng <br /> 2. Detached garages accessory to a dwelling located light and ventilation requirements, any room shall be cons�d- <br /> within 2 feet(610 mm)of a lot line are pernutted to ered as a portion of an adjoining room when at least one-half of <br /> have roof eave projections not exceeding 4 inches �e area of the common wall is open and unobsiructed and pro- <br /> (102 mm). � vides an,opening of not less than one-tenth of the floor area of <br /> 3. Foundation vents installed in compliance with this the interior room but not less than 25 square feet(2.3 mz). <br /> code aze pernutted. Exception: Openings required for light and/or ventilation <br /> shall be pemutted to open into a thermally isolated sunroom <br /> . .► addition or patio cover,provided that there is an openable <br /> SECTION R303 area between the adjoining room and the sunroom addition <br /> LIGHT,VENTILATION AND HEATING or patio cover of not less than one-tenth of the floor area of <br /> R303.1 Habitable rooms.All habitable rooms shall have an �e interior room but not less than 20 square feet(2 m2).The <br /> aggregate glazing area of not less than 8 percent of the floor ��mum openable area to the outdoors shall be based upon <br /> area of such rooms. Natural ventilation shall be through win- �e total floor area being ventilated. <br /> dows,doors,louvers or other approved openings to the outdoor R303.3 Bathrooms. Bathrooms, water closet compartments <br /> air.Such openings shall be provided with ready access or shall and other similar rooms shall be provided with aggregate glaz- <br /> otherwise be readily controllable by the building occupants. ing area in windows of not less than 3 square feet (0.3 m2), <br /> � The minimum openable azea to the outdoors shall be 4 percent one-half of which must be openable. <br /> of the floor area being ventilated. <br /> Exception:The glazed areas shall not be required where arti- <br /> Exceptions: ficial light and a mechanical ventilation system aze provided. <br /> 1. The glazed areas need not be openable where the The minimum ventilation rates shall be 50 cubic feet per min- <br /> opening is not required by Section R310 and an ute(24 Ls)for internuttent ventilation or 20 cubic feet per <br /> approved mechanical ventilation system capable of minute (10 L/s) for continuous ventilation. Ventilation air <br /> producing 0.35 air change per hour in the room is from the space shall be exhausted direcdy to the outside. <br /> TABLE R302.1 <br /> EXTERIOR WALLS <br /> MINIMUM MINIMUM FIRE <br /> EXTERIOR WALL ELEMENT FIRE-RESISTANCE RATING SEPARATION DISTANCE <br /> (Fire-resistance rated) 1 hour with ex sure from both sides 0 feet <br /> Walls <br /> (Not fire-resistance rated) 0 hours 5 feet <br /> (Fire-resistance rated) 1 hour on the underside 2 feet <br /> Projections <br /> (Not fire-resistance rated) 0 hours 5 feet <br /> Not allowed N/A <3 feet <br /> Openings 25%Ma�cimum of Wall Area 0 hours 3 feet <br /> Uniimited 0 hours 5 feet <br /> Com 1 with Section R317.3 <5 feet <br /> Penetrations • All <br /> None re uired 5 feet <br /> N/A=Not Applicable. <br /> 2006 INTERNATIONAL RESIDENTIAL CODE� 47 <br />