1999-012133 - fireplace insert
Orono
>
Property Files
>
Street Address
>
F
>
Fagerness Point Road
>
1815 Fagerness Point Road - 17-117-23-22-0033
>
Permits/Inspections
>
1999-012133 - fireplace insert
Metadata
Thumbnails
Annotations
Entry Properties
Last modified
8/22/2023 3:33:24 PM
Creation date
8/1/2016 12:45:05 PM
Metadata
Fields
Template:
x Address Old
House Number
1815
Street Name
Fagerness Point
Street Type
Road
Address
1815 Fagerness Point Road
Document Type
Permits/Inspections
PIN
1711723220033
Supplemental fields
ProcessedPID
Updated
There are no annotations on this page.
Document management portal powered by Laserfiche WebLink 9 © 1998-2015
Laserfiche.
All rights reserved.
/
10
PDF
Print
Pages to print
Enter page numbers and/or page ranges separated by commas. For example, 1,3,5-12.
After downloading, print the document using a PDF reader (e.g. Adobe Reader).
View images
View plain text
SCOPE: The following specifications , including special items and <br /> modifications , shall govern the construction of the fireplace <br /> and chimney. <br /> WORK INCLUDED: All labor, materials , equipment, appliances , anchors, <br /> bolts , miscellaneous iron work and all other reinforcing <br /> steel, as indicated on the plans and as herein specified. <br /> MATERIALS: Materials shall be as follows: <br /> -Water shall be clean and potable. <br /> -Sand conforming to "Aggregate for Masonry Mortar" , ASTM C144. <br /> -Portland cement conforming to ASTM C150. <br /> -Hydrated lime conforming to "Hydrated Lime for Masonry Purpose" , <br /> ASTM C207. Type S. <br /> -Steel reinforcing conforming to DEFORMED BILLET STEEL BARS <br /> CONGRETE REINFORCEMENT ASTM A615 - Grade 40. <br /> -Brick, meeting the requirements for "Building Brick" , ASTM C62. <br /> -Block meeting the requirements for "Solid Load Bearing Concrete <br /> Masonry Units" , ASTM C145-71. <br /> -Flue lining conforming to Clay Flue Linings , ASTM C315 . <br /> MORTAR PROPORTIONS: TABLE N0. 24-A MORTAR PROPORTIONS <br /> (Parts by Volume) <br /> - — -- - . _ _—--- –--– _ _ ----- -----_ _ ----- _- <br /> t'I';:�.''" .,O.Tr...�57�'E ...:iF::Tc-L t iwfc5 I ,;,•;y <br /> 1i)i�,TAR ST'rr,��:H A7' 2�' U:�,YS I'(ikTl�+tiD Oi: ;_I".E 1'L'"�"TY :%-.S(;':F.1' ].��US� <br /> 1E -- (�_s.i�----- Cc�^1E!�T_ "I\. `�•J!. Ci:.•`F1TS FGGkz.:J�TE <br /> 1 - 1/4 -�j�— `�o: ;css than <br /> M _ 2500 1 - - � 1 2-1/4 and nat <br /> 1 1/4 1/�— rore than 3 <br /> � S ]800 1/2 - 1 tines the s� <br /> — � 1--- 1/2 1-1/4 - o.' the ��n:ures <br /> _T� 750 _ � - __-__ = --} 1 of [ne cr nen; <br /> 0 350 � 1 1-1/4 ?-1/z I and !ir.�e usez <br /> -- — ---- ----- ---- ---- -- -�----- ----- <br /> ti�en p]asttc oz katerproof ce�,ent is used as specified in Section 2403 (p). hyd-ated lime <br /> or putty r�ay be added bv[ not in excess of one-tenth the volu.�e of cr�enc. <br /> MIXING OF MORTAR: A11 cementitious materials and aggregates shall be <br /> mixed for a minimum period of three minutes, with <br /> the amount of water required to produce the desired <br /> workability. Type 0 Mortar is not recommended for <br /> fireplace construction. <br /> RE-TEMPERING: Permitted only by adding water within a basin formed <br /> of mortar and the mortar reworked into the water. <br /> Mortar which has become harsh and non-plastic shall <br /> not be re-tempered or used. <br />
The URL can be used to link to this page
Your browser does not support the video tag.