My WebLink
|
Help
|
About
|
Sign Out
Home
Browse
Search
03-19-2007 Planning Commission Packet
Orono
>
Planning Commission
>
2007
>
03-19-2007 Planning Commission Packet
Metadata
Thumbnails
Annotations
Entry Properties
Last modified
6/19/2012 4:41:09 PM
Creation date
6/19/2012 4:40:41 PM
Metadata
Jump to thumbnail
< previous set
next set >
There are no annotations on this page.
Document management portal powered by Laserfiche WebLink 9 © 1998-2015
Laserfiche.
All rights reserved.
/
529
PDF
Print
Pages to print
Enter page numbers and/or page ranges separated by commas. For example, 1,3,5-12.
After downloading, print the document using a PDF reader (e.g. Adobe Reader).
Show annotations
View images
View plain text
503.2.4-506.2 FIRE SERVICE FEATURES <br /> � 503.2.4 Ttirning radius.The required turning radius of a apparatus access roads to exterior openings shall be provided -- <br /> fire apparatus access road sha11 be determined by the code when required by the code official: <br /> ����� 504.2 Maintenance of exterior daors and openings.Exterior � <br /> 503.2.5 Dead ends.Dead-end fire apparatus access roads in doors and their function shall not be eliminated without prior <br /> �( excess of 150 feet(45 720 mm)in length shall be provided approval.Exterior doors that have been rendered nonfuncfional <br /> with an approved area for turning around fire apparatus. and that retain a functional door extarior appearance shall have <br /> . 503.2.6 Bridges and etevated surfaces.Where a bridge or a sign affixed to the exterior side of the door with the words <br /> an elevated suiface is part of a fire apparatus access road,the THIS DOOR BLOCKED.The sign shall consist of letters hav- <br /> bridge shall be constructed and maintained in accordance �g a principal stroke of not less than 0.75 inch(19.1 mm)wide `� <br /> with AASHTO Standard Specification for Highway �d at least 6 inches (152 mm) high on a contrasting back- <br /> Bridges.Bridges and elevated surfaces shall be designed for gTOUnd.Required fire department access doors shall not be ob- <br /> a live load sufficient to carry the imposed loads of fire appa- strncted or eIiminated.Exit and exit access doors shall comply <br /> ratus.Vehicle load limits shall be posted at both entrances to ���P�r 10.Access doors for high-piled combustibte stor- _ <br /> bridges wnen required by the code o�cial.�Vhere elevated age s�comply�vith Section 23Q5.6.1. <br /> surfaces designedfor emergency vehicle use are adjacent to 504.3 Stairway access to roof. New buildings four or more -� <br /> surfaces which aze not designed for such use,approved bar- $tories in height, except those with a roof slope greater than <br /> riers, approved signs or both shall be installed and main- four units vertical in'12 units horizontal(333-percent slope), <br /> tained when required by the code official. shall be provided with a stairway to the roof. Such stairway <br /> 503.2.7 Grade.The grade of the fire apparatus access road shail be marked at street and floor levels with a sign indicating • <br /> shall be within the limits established by the cade official ' �at the stairway continues to the roof.Where roofs are used for <br /> based on the fire department's apparatus. roof gazdens or for other pucposes,stairways shall be provided <br /> as required for such occupancy classification. <br /> 5033 Marking.Where required by the code official,approved . ' <br /> signs or other approved notices shall be provided for fire appa- <br /> ratus access roads to identify suchroads orprohibit the obstruc- <br /> tion thereof.Signs or nofices shall be maintained in a clean and SECTION 505 • <br /> legible condition at aIl times and be replaced or repaired when PREMISES IDENTIFICATION <br /> necessary to provide adequate visibility. 505.1 Address numbers. New and existing buildings shall <br /> 503.4 Obstraction of fire apparatus access roads.Fire appa- have approved address numbers, building numbers, or ap- ,J <br /> ratus access roads shall not be obs�ucted in any manner,in- pI'oved building identification placed in a position to be plainly ' <br /> cluding the parking of vehicles. The minimum widths�and legible and visible from the street orroad fronting the progerty. <br /> clearances established in Section 503.2.1 shall be maintained '�ese numbers shall contrast with their background.Address <br /> � at all times. numbers shall be Arabic numerals or alphabet letters.Numbers <br /> � shall be a minimum of 4 inches(102 mm)lugh with a minimum � <br /> 5035 Required gates or barricades.The code officiat is au- � stroke width of 0.5 inch(12.7 mm). <br /> thorized to require the installation and maintenance of gates or <br /> other approved barricades across fire apparatus access roads, 505.2 Street orroad signs.Streets and roads shall be identified <br /> trails or other accessways,not including public streets,alleys with approved signs.Temporary signs shalI be installed at each <br /> o�ti'igttways. treet interseetio�when=eonstivetion°o€=new--roadways-allow <br /> 503.5.1 Secured gates and barricades. When required, P�sage by vehicles.Signs shall be of an approved size,weather <br /> gates and barricades shall be secured in an approved man- resistant and be maintained until replaced by permanent signs. <br /> ner.' Roads, trails and other accessways that have been . <br /> closed and obstructed in the manner prescribed by Section � � <br /> 503.5 shall not be trespassed on or used unless authorized by SECTION 506 . � <br /> the owner and the code official. � KEY BOXES <br /> Exeeption:The restriction on use shalI not apply to pub- X SOb.l When required.Where access to or within a structure or <br /> Iic officers acting within the scope of duty. an area is restricted because of secured openings or where im- <br /> 503.6 Security gates.Where security gates a�re installed,they �ediate access is necessary for life-saving or fire-fighting pur- ' <br /> shall be maintained and an approved means of emergency oper- Poses,the code official is authorized to require a key box to be <br /> ation shall be provided and maintained. �t����accessible locarion The key box shall be of an � <br /> . approved type and shall contain keys to gain access as required ` <br /> by the code official. <br /> SECTION 504 506.2.1 Locks.An approved lock shall be installed on gates <br /> ACCESS TO BUILDING OPENINCaS AND ROOFS or similar barriers when required by the code official. <br /> 5fi4.I Reguired access.Exterior doors and openings required 506.2 Key Tnox maintenance. The operator of the buitding � <br /> by this code or the International Building Code shall be main- shall immediately notify the code official and provide the new � <br /> tained readily accessible for emergency access by the fire de- � key when a lock is changed or rekeyed.The key to such lock <br /> partment. An approved access walkway leading from ftre shall be secured in the key box. ' <br /> 40 � • 200f11NTERNATIANAL FIRE CADEW � <br />
The URL can be used to link to this page
Your browser does not support the video tag.