My WebLink
|
Help
|
About
|
Sign Out
Home
Browse
Search
2015-00725 - new structure
Orono
>
Property Files
>
Street Address
>
E
>
Ethel Avenue
>
2755 Ethel Avenue - 20-117-23-24-0017
>
Permits/Inspections
>
2015-00725 - new structure
Metadata
Thumbnails
Annotations
Entry Properties
Last modified
8/22/2023 3:54:27 PM
Creation date
7/28/2016 5:06:24 PM
Metadata
Fields
Template:
x Address Old
House Number
2755
Street Name
Ethel
Street Type
Avenue
Address
2755 Ethel Avenue
Document Type
Permits/Inspections
PIN
2011723240017
Supplemental fields
ProcessedPID
Updated
There are no annotations on this page.
Document management portal powered by Laserfiche WebLink 9 © 1998-2015
Laserfiche.
All rights reserved.
/
48
PDF
Print
Pages to print
Enter page numbers and/or page ranges separated by commas. For example, 1,3,5-12.
After downloading, print the document using a PDF reader (e.g. Adobe Reader).
View images
View plain text
. � ' <br /> GENERAL NOTES: <br /> 1. Wall thicknesses noted are nominal unless specifically stated otherwise. <br /> 2. Maximum wall to footing centerline offset is 2". A minimum of 2"of footing is to extend on each side of the wall. <br /> 3. Bar laps when required are to be at least 40 bar diameters for grade 40 and 60 bar diameters for grade 60. <br /> 4. Bend horizontal bars or provide matching hooks around all wall corners and intersections. <br /> 5. Horizontal bars may be placed anywhere within the wall thickness provided 2"minimum cover is provided. <br /> 6. Allowable bar placement tolerance is 1l2". Tying is not required if tolerances are met and maintained. <br /> 7. Dowels may be drilled and installed afterfooting pour unless otherwise noted. Vertical bars may be embedded <br /> into footing in place of dowels at the same embedment. Vertical bars and dowels do not need to align. Dowels <br /> may be bent down for safety and covering then bent back before wall placement. <br /> 8. Sill plate sections require at least two anchors with one within 4"to 12"of each end and at all corners and <br /> intersections. Walls less than 24"in length require only one anchor. Sill plates are not to overhang face of wall <br /> without further review. <br /> 9. Anchor bolts 1/2"or larger in diameter do not require corrosion protection per IRC section R317.3.1 exception 1. <br /> 10. Anchor bolts may be substituted with 1/2"diameter threaded rod epoxy grouted at same spacing with 7"embed. <br /> 11. The presence of form oil on the reinforcing is acceptable for the conditions contained in these drawings. <br /> 12. Slope grade 6"minimum downward away from foundations within�rst 10 feet or provide Code adequate swale. <br /> 13. Do not backfill until the concrete has reached at least 70 percent of the 28 day concrete strength. Use of <br /> adequate shoring is required when the final floor and slab systems are not in place and fully anchored. <br /> 14. Maximum inside window well dimension is 72". Well walls are to be at least 8"thick placed monolithically with <br /> house walls with horizontal bars extended into them and around corners. Provide two additional vertical bars and <br /> one additional anchor bolt each side of opening. Opening header by others. <br /> COLD WEATHER GUIDELINES: <br /> The following information is general guidelines for the placement of concrete in cold weather conditions. It is the <br /> contractor's responsibility to ensure proper means and methods are followed and that the final in place product is <br /> adequate. <br /> 1. The contractor is to work with the concrete supplier to obtain a mix design which accounts for the conditions <br /> expected. Use of extra cement,early-strength concrete,and accelerators are recommended at temperatures <br /> below 20 degrees F. <br /> 2. Concrete is to be delivered to the site in a timely manner. <br /> 3. Placement of concrete earlier in the day to take advantage of latent heat of sunlight is advised. <br /> 4. Do not add additional water. Using water-reducing admixtures is recommended when required. <br /> 5. Forms are to be free of snow and ice. Do not place concrete in contact with frozen ground,snow,or ice. <br /> 6. Preheating of rebar is not required, however it is to be free of frost,snow,and ice. <br /> 7. Use of form blankets or other approved protection is highly recommended for the top of the wall at temperatures <br /> below 10 degrees F and for the whole wall when below zero degrees F. <br /> Oswell Engineering a�d Consulting,L.L.C. 1901 E Hennepin Ave,#201 ��` :�'.r�:* . <br /> Project Name: 2015 Standardized Concrete Foundation Drawings Minneapolis,MN 55413 � <br /> Description: General Notes Phone:612-720-4639 `• " <br /> Project# 14.100 Fax:612-886-2968 <br /> Client Name: Kopp Concrete Inc www.oswellec.com <br /> Client Address: 16455 122nd Street,Becker,MN 55308 Page S2 of S6 ` •" .,;,=4'. <br /> 1124/2015 <br />